FCM
Series
Process data IN
PD
PD0
PD1
Bit
79
78
77
76
75
74
73
72
71
70
69
68
67
66
65
64
MSB
LSB
Data name
Integra
ting flow unit upper
byte
Data range
2 byte
Format
UInteger16
PD
PD2
PD3
Bit
63
62
61
60
59
58
57
56
55
54
53
52
51
50
49
48
MSB
LSB
Data name
Integrat
ing flow unit lower
byte
Data range
2 byte
Format
UInteger16
PD
PD4
PD5
Bit
47
46
45
44
43
42
41
40
39
38
37
36
35
34
33
32
MSB
LSB
Data name
Se
t flow rate *1
Data range
2 byte
Format
UInteger16
PD
PD6
PD7
Bit
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
MSB
LSB
Data name
Instantaneou
s flow rate *2
Data range
2 byte
Format
Integer16
PD
PD8
PD9
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Data name Error WARNING Normal
operation
-
Switch output *3
MSB
LSB Input setting
*4
Accumulated
auto cutoff
occurring
Start/stop
4
3
2
1
Error code
Data range
True/False
0 to 15
0 to 2
True/False
Format
Boolean
UInteger4
UInteger2
Boolean
*1: Displays the configured fl
ow rate for the current input setting.
"9999" means "valve fully open". (Refer to the Process data OUT item.)
*2: For
instantaneous flow
rates a negative value is used to check the shift from the zero point and does not indicate a revers
e flow.
Switch output
Switch function
1
Tolerance mode
2
Designated range mode
3
Integrated pulse
4
ON at set integration or higher
Input setting
Input mode
0
Normal mo
de (flow rate value)
1
Preset mode (3 bit)
2
Direct memory mode (key operation)
*3
*4
15
Summary of Contents for FCM-0001 AI
Page 29: ...ME M O MEMO 24 ...