8
Cable
AX
Series
Cable specifications
Safety precautions
When connecting the motor cable and driver, check that the cable's mark tubes and the driver's indications
are correct.
Fix the cable by the cable sheath near the actuator if the cable will be bent repeatedly.
The outlet cable of the AX4009T and AX2000T are not flexible. Always fix these cables near the connector to
prevent it from moving. Pulling and applying excessive force to the cable may damage the cable.
When connecting the cable, insert the connector securely to the back. Tighten the connector's set screws
and fixing screws.
Do not modify cable by cutting or extending it as it may lead to faults or malfunctions.
Refer to "How to order" for cable length of L.
Cable specifications
AX1000T
Resolver cable
Movable cable
60mm
Motor cable
110mm
AX2000T and AX4000T
Resolver cable
60mm
Motor cable
110mm
UN
Resolver cable
Motor cable
(43)
(12)
(18.5)
L (cable length)
(100)
Φ45 (Maximum diameter)
Φ21 (Maximum diameter)
UN
Resolver cable
Motor cable
(43)
(12)
(18.5)
L (cable length)
(100)
Φ45 (Maximum diameter)
Φ21 (Maximum diameter)
(12)
(22)
(15)
Motor cable
(100)
L (cable length)
(16)
(14)
Resolver cable
(43)
(18.5)
(12)
(22)
(15)
Motor cable
(100)
L (cable length)
(16)
(14)
Resolver cable
(43)
(18.5)
Cable min. bending radius
Cable dimensions