72
AX-OPX
Series
Cautions on connection
Serial transmission slave unit
CC-Link/DeviceNet
Connecting the pulse string input connector (option)
When connecting a pulse string input cable (option model: AX-OPX-CABLE-D02), disconnect the short-circuit connector with a narrow flat-tipped
precision screwdriver , align notches on the male and female connectors, and insert the connector.
Do not disconnect the short-circuit connector by pulling on the short-circuit jumper wire.
Refer to "Safety Precautions" in the instruction manual before use.
Read through the instruction manual for the communication system and be sure you understand it before use.
Do not install this product where water, moisture, dust, or oil fumes are generated. Failure to observe this could cause fire, faults or electrical
shock, etc.
If the slave switch is set incorrectly, the direct drive actuator could malfunction. Carefully confirm switch settings before use. Check the slave
number, transmission speed and output settings at communication error when power is turned on.
Turn power off before starting wiring.
When connecting the cable to the connector, the cable could move to the back instead of the connector tightening side, so always loosen the
cable fixing screw sufficiently.
If a connector fixing screw is provided, tighten it when inserting the connector. If the screw is not tightened, the connector could deviate and
malfunction. If a connector fixing screw is not provided, confirm that connector latches are caught firmly.
Provide sufficient bending radius for the communication cable so it is not bent forcibly.
Disconnecting the slave by pulling on the cable or connector could cause wire breakage or damage. Hold the slave when removing it.
Touching electric connections (live parts) could cause electrical shock.
The AX driver's M code output (bit 6) and M code output (bit 7) cannot be used.
Safety precautions
SLD
FG
DA
DG
RD
L
RUN
DB
PW
SD
L
ERR
Precise screw driver
Short connector
Connector (male)
2120
±
50
Electric wire size (AWG26)
Notch
Installation
The slave's depth is 68 mm and the plug's depth is 16.5 mm.
The slave is removed with the plug wired.
The slave's vertical orientation is reversed when installed onto the GH or H
driver. The switch faces up.
Fix the slave on the driver with fixing screws.
GH/H type driver installation