![CKD ABSODEX AX1022 Manual Download Page 33](http://html1.mh-extra.com/html/ckd/absodex-ax1022/absodex-ax1022_manual_2611691033.webp)
12
AX4000G
Series
Dimensions
AX4000G
Actuator
Dimensions
AX4022G
AX4022G-EB
With electromagnetic brake
Refer to the left drawing for other options.
Recommended value for
lead wire relief dimensions
4-M6 depth 12 (straight)
(Screw valid length 9)
For dial plate mounting
Rotational section
(including hollow
section)
170
180
±
2
140h7
100h7
5
P.C.D.160
(9.5)
95
28.5
4-M6 depth 12 (straight)
(Screw valid length 9)
For dial plate mounting
4-M6 depth 12 (straight)
Rotational section
(including hollow section)
P.
C.
D.
1
60
170
180
±
2
140h7
100h7
119.5
5
70
P.C.D.160
(9.5)
95
28.5
Electromagnetic brake lead wire
300 from outlet
25
5˚
3-M5 (straight)
Electromagnetic brake for manual release
45˚
5˚
14
0
R8
45.2
10
Electromagnetic brake
(protection element attached)
109.5
C10
200
150
6H7 depth 8 (option)
4-M6 depth 12 (straight)
For option electromagnetic brake mounting
P.C
.D.5
4
4
5
˚
150
200
45
CAUTION:
When using flexible cable,
fix the end of cable sheath.
24
Standard cable length 4m
80
Cable bending range
(Cable bending range
downward is 60.)
24
Standard cable length 4m
65
44
4- 7
Mounting base (option)
12
4-M6 depth 12 (straight)
P.C
.D.
160
P.C.D.125
3-M6 depth 12 (straight)
For option electromagnetic
brake mounting
6H7 depth 8 (option)
Not available if the option base is installed.
88
63
63
32
32
115
(10)
20.5
45˚
0.06 A
0.06 B
A
B
80
80
P.C
.D. 1
22
37.5
˚
Summary of Contents for ABSODEX AX1022
Page 21: ...Intro 20 MEMO...
Page 71: ...50 MEMO...
Page 77: ...56 MEMO...
Page 85: ...64 MEMO...
Page 95: ...74 MEMO...
Page 102: ...81 MEMO...
Page 103: ...82 MEMO...
Page 104: ...2007 11 DCC...