Operating Mode Configuration
Factory configuration:
Charging Authorisation:
Always authorised, free to use
Maximum Charging Current:
16A
Back Office Communications
Disabled
Configuration Programming:
1.
Press Start/Stop switch
2.
Swipe master Key fob
Middle green LED flashes
3.
Within 20 seconds press start/stop switch
Top LED flashes to indicate charge authorisation mode
Top LED flashes in groups to indicate currently programmed authorisation mode as follows:
1 flash = Always authorised, free to use
- - - -
2 flashes = Free to use but enabled/disabled by key fob
- - - - - - - -
3 flashes = Each charging session authorised by key fob
- - - - - - - - -
4.
Press start/stop switch to change mode