Operating Mode Configuration 
 

Factory configuration: 
 

Charging Authorisation:    

Always authorised, free to use 

 
Maximum Charging Current: 

16A 

 
Back Office Communications 

Disabled 

 

Configuration Programming: 

 

1.

 

Press Start/Stop switch 

2.

 

Swipe master Key fob 

 

 

 

 

Middle green LED flashes  

 

 

 

3.

 

Within 20 seconds press start/stop switch 

 

 

Top LED flashes to indicate charge authorisation mode

 

 

 

 

 

 
Top LED flashes in groups to indicate currently programmed authorisation mode as follows: 
 
1 flash = Always authorised, free to use 

-       -     -     -      

2 flashes = Free to use but enabled/disabled by key fob 

- -   - -   - -   - -    

3 flashes = Each charging session authorised by key fob 

- - -   - - -   - - -      

4.

 