The PDS-375 TR Power Supply™ page 4
TM
PATENT PENDING
PDS-375-TR
6
5
4
3
2
1
FAULT
DMX:
STATUS
RESET
CONFIG
1's
10's
100's
Figure 1, PDS-375 TR, Front Panel
Front Panel Controls
The PDS-375 TR front panel controls will generally look familiar to most professional users,
with a Pilot/Status Light, 3 BCD DMX Address Switch array, and a system reset switch. In
addition, the unit is provided with a Configuration BCD, overload indicators, and a Mini-Zapi™
Switch. All the control functions are described below:
1. Pilot / Status Light:
On = Power Present, System running
Blinking = No DMX
Solid = DMX Present
Green = CB Mode
Orange = Pass Thru Mode
Alternating Red/Green = Stand Alone Mode
2. Reset Switch: Press to reset the PDS-375 TR’s system microprocessor
3. DMX Address Switches: Left to right =
100’s, 10’s, 1’s
Set address to 000 for Pass Thru mode
Set address to any valid address 001 – 476
1
for CB mode
1
The unit may be addressed to start at
any
DMX value up to 512, however addresses above 476 will
waste outputs, as DMX values will not exist for all outputs.