The PDS-375 TR Power Supply™ page 10
2 10/sec
3 7.5/sec
4 5/sec
5 4/sec
6 3/sec
7 2/sec
7
Variable color strobe steps from color to color (Red, Green, Yellow, Blue, Magenta,
Cyan, & White) in a user definable time period at a strobe rate that is also user
definable. The same strobe rate that is employed in the fixed color strobe is
available via the DMX 1s digit. The step times between color changes are provided
via the DMX 100s and 10s switches. The values and time periods are the same as
the random color effect.
Using the Mini-Zapi
CB fixtures can be quickly re-addressed as “Light 1” (DMX 001, 002, & 003) using the Mini-
Zapi.
1. Power Up the PDS-375 TR
2. Place the PDS-375 TR into Pass-Thru Mode
3. Connect the CB Fixture(s) to the PDS-375 TR.
4. Press the Mini-Zapi button.
5. The CB fixture(s) will light red for a moment and then flicker for a few seconds.
6. After the flickering stops, Power the system down.
7. Power the system back up to test the units.
Installing the PDS-375 TR
The PDS-375 TR can be mounted to a pipe or truss
using a standard theatrical C-clamp. The unit is
provided with a ½” hole in the center of the handle for
attaching the C-clamp, and with holes in the handle base
for a safety cable. When mounting the PDS-375 TR in
this way, all necessary care should be taken to assure
that the installation is suitable and safe, and that the
hardware is properly rated for the task.
The PDS-375 can also be setup on a table, shelf, or
other suitable flat surface. Be sure that adequate
clearance for ventilation is maintained. Do NOT seal the
PDS-375 up in a box or other un-cooled enclosure. If
environmental protection is required, the unit may be
installed in a suitable and
properly ventilated
NEMA 3R
enclosure. Contact City Theatrical for details.
Figure 3 PDS-375 TR with C-Clamp