The PDS-375 TR Power Supply™ page 5
4. Configuration Switch: Selects Stand-Alone Routines. Also may be used for special
functions
5. Channel Overload Indicator: Lights if internal circuit breaker is tripped, indicating an
overloaded output. If tripped, disconnect load and allow unit to cool (~ 2 minutes). Circuit
breaker will re-set.
Note: If internal circuit breaker trips, something is wrong.
Correct fault before using system!
6. Mini-Zapi™: Resets any connected Color Kinetics CB fixtures to
Light 001
(DMX 001,002
& 003), preparing them for easy use with the CB Mode setting
7. Fan, do not obstruct.
PILOT LED KEY
red/green: STAND-ALONE
blinking: NO DMX
solid: DMX PRESENT
orange: PASS-THRU
green: CB MODE
752 E. 133rd STREET, BRONX NY 10454
VOICE: 718-292-7932 FAX: 718-292-7482
RED
WHITE
BLACK
GND
DATA
n/c
+24VDC
PIN 4
PIN 3
PIN 2
PIN 1
4P XLR PIN OUT
1 CB12, 2 CB6s, OR 8 iCOLOR COVES MAX PER OUTPUT
1
2
3
4
5
6
DMX OUT
DMX IN
FUSE 5 AMPS
NEMA 1 ENCLOSURE
MANUFACTURED BY
CAN/CSA STD C22.2 NO. 14-95
CERTIFIED TO
C
MIXED VOLTAGE INTERFACE PANEL
9801635
ETL LISTED
CONFORMS TO UL STD 508A
6 x 3 AMPS 24VDC MAX OUTPUT
100-240 VAC 50/60Hz 5A MAX INPUT
US
REFER TO QUALIFIED PERSONNEL
NO USER SERVICABLE PARTS INSIDE
Figure 2, PDS-375 TR, Back Panel
Back Panel Features
8. IEC Power Inlet, Connect Mains Power Cord here.
9. DMX OUTPUT, 5P XLR Female Panel Mount connector, a re-generated, optically isolated
DMX output (the Unit switches to passive hard-wired pass-thru if power is lost).
10. DMX INPUT, 5P XLR Male Panel Mount connector, auto-terminated
11. Fixture Output # 1, 4P XLR Female, for connection of Color Kinetics fixtures
12. Fuse (5A 3AG)