Citrix ADC MPX
The following components are visible on the back panel of the MPX 15000-50G appliances:
• Two 480 GB or larger removable solid-state drives in a redundant array of independent disks
(RAID) configuration. In a RAID configuration, the same data is stored on multiple drives to im-
prove performance, increase storage capacity, lower the risk of data loss, and provide fault tol-
erance. The two SSDs store the same data. If one fails and you replace it, the new SSD mirrors
the other one.
Note:
Drive densities might increase as components become EOL but its size is never smaller
than the original.
• Power switch, which turns power to the appliance on or off.
–
If the OS is functional, press the switch for less than two seconds to power down the system
with a graceful shutdown.
–
If the OS is not responsive, press the power switch for more than 4 seconds to force the
power off.
• Two hot-swappable 100–240 VAC input power supply modules, rated at 1000 watts each. Maxi-
mum power consumption is 522 watts and typical power consumption is 300 watts. The follow-
ing table indicates the LED status of each power supply:
LED Color
LED Indicates
OFF
No power to any power supply on the
appliance.