Citrix ADC MPX
1
root@ns
#
atacontrol detach ata2
2
<!--
NeedCopy
-->
2. Physically, remove SSD 1/drive 0 and replace it with a new FRU drive in slot 1.
3. Attach the FRU drive.
1
root@ns
#
atacontrol attach ata2
2
<!--
NeedCopy
-->
4. Add the FRU drive to the RAID array.
1
root@ns
#
atacontrol addspare ar0 ad4
2
<!--
NeedCopy
-->
5. Verify that the replacement drive is recognized.
1
root@ns
#
atacontrol status ar0
2
<!--
NeedCopy
-->
Output:
1
ar0
:
ATA RAID1 status
:
DEGRADED
2
subdisks
:
3
0
ad4
SPARE
4
1
ad6
ONLINE
5
<!--
NeedCopy
-->
6. Start the rebuild process.
1
root@ns
#
atacontrol rebuild ar0
2
<!--
NeedCopy
-->
7. Monitor the rebuild process.
© 1999
‒