![Citrix ADC MPX 5550 Manual Download Page 210](http://html1.mh-extra.com/html/citrix/adc-mpx-5550/adc-mpx-5550_manual_2611002210.webp)
Citrix ADC MPX
Example:
scp
/
nsconfig
/
ssl
/
nodeA
.
key nsroot@198
.51.100.10:/
nsconfig
/
ssl
15. Import the FIPS keys on appliance B.
Example:
import
fipskey Key
-
FIPS
-2 -
key Key
-
FIPS
-2.
key
-
inform SIM
-
exponent F4
16. Copy the certificate files to appliance B, in the
/
nconfig
/
ssl
folder.
Example:
scp
/
nsconfig
/
ssl
/
nodeA
.
cert nsroot@198
.51.100.10:/
nsconfig
/
ssl
17. Copy the rest of the configuration from appliance A to appliance B.
Troubleshooting
September 19, 2022
I cannot access the Citrix ADC appliance after it is restarted. The Citrix ADC IP address
(NSIP) is not accessible and does not respond to a ping request
Citrix ADC MPX 8005/8015/8200/8400/8600/8800, MPX 11500/13500/14500/16500/18500/20500, MPX
11515/11520/11530/11540/11542, MPX 17550/19550/20550/21550, MPX 22040/22060/22080/22100/22120,
MPX 24100/24150, MPX 25100T/25160T, T1010, T1100, T1200, T1300, and T1310 appliances support
LOM. Depending on the state of the LOM configuration, start with one of the steps in the following
procedure. To configure the LOM port, see
Lights out management port of the Citrix ADC appliance
.
1. If the LOM port is configured and known to have been working previously, log on to the LOM
GUI, and perform the following steps:
a) Navigate to
Remote Control
>
Console Redirection
, and then click
Launch Console
.
b) On the Java iKVM Viewer screen, check the VGA console window for boot errors, such as
bad or missing boot media (boot drive/Compact Flash card). Reseat any unconnected boot
media. If the appliance boots up, try to log on and run the
show techsupport
command
from the Citrix ADC command line. Complete the Check Network Interfaces steps to find a
working interface on which to transfer the support bundle file.
c) Navigate to
System Health > Sensor Readings
to check the status of the hardware com-
ponents (for example, CPU temperature, system temperature, and power supply status).
You might have to scroll down. Green indicates that the hardware component is function-
ing properly. Red indicates that it has failed. Contact Citrix Support if you observe red
indicators.
© 1999
‒
2022 Citrix Systems, Inc. All rights reserved.
210
Summary of Contents for ADC MPX 5550
Page 1: ...Citrix ADC MPX Citrix Product Documentation docs citrix com November 17 2022...
Page 15: ...Citrix ADC MPX 1999 2022 Citrix Systems Inc All rights reserved 15...
Page 16: ...Citrix ADC MPX 1999 2022 Citrix Systems Inc All rights reserved 16...
Page 132: ...Citrix ADC MPX 1999 2022 Citrix Systems Inc All rights reserved 132...