The controller compares the temperatures at the collector
sensors S1 and S5 to the store temperatures at the sensors
S2 and S3. If one of the measured temperature differences is
higher than the adjusted switch-on temperature differences,
the corresponding pump (R1, R2) or both pumps will be
activated and the corresponding store zone will be loaded
up to the adjusted maximum temperature via the valve (R3).
The priority logic effects prior loading of the upper zone
of the store.
Adjustment channels
Channel
Description
Page
ARR
System
45
LOAD1 >
Loading 1
45
LOAD2 >
Loading 2
48
COL 1 >
Collector 1
50
COL 2 >
Collector 2
51
LLOGI >
Loading logic
52
COOL >
Cooling functions
53
PUMP >
Pump speed
47
MAN >
Manual mode
54
BLPR >
Blocking protection
54
OPARR >
Parallel relay option
55
OHQM >
Heat quantity measurement option
55
Sensor/Ter-
minal
Designation
Description
S1
TCOL1
Temperature collector 1
S2
TSTB
Temperature store base
S3
TSTT
Temperature store top
S4
Optional sensor for measurement
purposes or options
S5
TCOL2
Temperature collector 2
VFS
Optional sensor for measurement
purposes or options
RPS
V40
Relay
Description
R1
Solar pump collector 1
R2
Solar pump collector 2
R3
3-port valve store top/base
R4
optional:
Parallel relay
System 22
Solar system with store loading in layers and east-/west collectors
R3
R2
R1
S5
S3
S2
S1
Temp. Sensor
Pt1000
L
R3
R2
R1
GND
S1
S2
S3
S4
S5
VBus
PWM
1
PWM
2
N
R4
V40
L'
VFS
RPS
out
in
Note: 3-port valve normally open - store top (S3)
Adjustment channels
Channel
Description
Page
GFDS >
Registration Grundfos sensors
55
PRS* >
Pressure monitoring option
57
DATE>
Enter date
57
LANG >
Language
58
UNIT >
Unit
57
OSDC >
SD card option
58
CODE
User code
62
RESET
Factory setting
59
* This channel is only available if the Grundfos sensors have been
registered in the GFDS channel.
** are blocked against each other
Note:
The parameter
LOAD1 refers to
S2, the parameter
LOAD2 2 to S3.