© Citrin 11234 CS 2.5.monen.ind
d
Page 25
CitrinSolar CS 2.5
CitrinSolar Energie- u. Umwelttechnik GmbH
•
Böhmerwaldstr. 32
•
D-85368 Moosburg
•
Tel.:+49 (0) 8761/33400
•
Fax: +49 (0) 8761/334040
The controller compares the temperature at sensor S1 to
the temperatures at sensors S2 and S3. If the measured
temperature differences are higher than the adjusted switch-
on temperature differences, the pump (R1) will be activated
and the corresponding store zone will be loaded up to the
adjusted maximum temperature via the valve (R3).
The priority logic effects prior loading of the upper zone
of the store.
Heat exchange control to an existent store via an additional
pump (R2) can be carried out with another temperature
differential function (S3 heat source/S4 heat sink).
Sensor/Ter-
minal
Designation
Description
S1
TCOL
Temperature collector
S2
TST1B
Temperature store 1 base
S3
TSTT
Temperature store 1 top
S4
TST2B
Temperature store 2 base
S5
Optional sensor for measurement
purposes or options
VFS
RPS
V40
Relay
Description
R1
Solar pump
R2
Heat exchange pump
R3
3-port valve store top/base
R4
optional:
Parallel relay
System 11
Solar system with store loading in layers and heat exchange control
Adjustment channels
Channel
Description
Page
ARR
System
45
LOAD1 >
Loading 1
45
LOAD2 >
Loading 2
48
COL >
Collector
50
LLOGI >
Loading logic
51
COOL >
Cooling functions
52
DT3 >
Heat exchange
53
PUMP >
Pump speed
47
MAN >
Manual mode
54
BLPR >
Blocking protection
54
OPARR >
Parallel relay option
55
OHQM >
Heat quantity measurement option
55
R2
R3
S3
R1
S4
S2
S1
Temp. Sensor
Pt1000
L
R3
R2
R1
GND
S1
S2
S3
S4
S5
VBus
PWM
1
PWM
2
N
R4
V40
L'
VFS
RPS
out
in
Note: 3-port valve normally open - store top (S3)
Adjustment channels
Channel
Description
Page
GFDS >
Registration Grundfos sensors
55
PRS* >
Pressure monitoring option
57
DATE>
Enter date
57
LANG >
Language
58
UNIT >
Unit
57
OSDC >
SD card option
58
CODE
User code
62
RESET
Factory setting
59
* This channel is only available if the Grundfos sensors have been
registered in the GFDS channel.
** are blocked against each other
Note:
The parameter
LOAD1 refers to
S2, the parameter