![CitrinSolar CS 2.5 Mounting And Operating Instructions Download Page 26](http://html1.mh-extra.com/html/citrinsolar/cs-2-5/cs-2-5_mounting-and-operating-instructions_2610981026.webp)
© Citrin 11234 CS 2.5.monen.ind
d
Page 26
CitrinSolar CS 2.5
CitrinSolar Energie- u. Umwelttechnik GmbH
•
Böhmerwaldstr. 32
•
D-85368 Moosburg
•
Tel.:+49 (0) 8761/33400
•
Fax: +49 (0) 8761/334040
The controller compares the temperature at sensor S1 to
the temperatures at sensors S2 and S3. If the measured tem-
perature differences are higher than the adjusted switch-on
temperature differences, the pump (R1) will be activated and
the corresponding store zone will be loaded up to the adju-
Sensor/Ter-
minal
Designation
Description
S1
TCOL
Temperature collector
S2
TSTB
Temperature store base
S3
TSTT
Temperature store top
S4
Optional sensor for measurement
purposes or options
S5
VFS
RPS
V40
Relay
Description
R1
Solar pump
R2
optional:
Parallel relay
R3
3-port valve store top/base
R4
Afterheating/store loading pump
System 12
Solar system with store loading in layers and thermostatic afterheating
R3
R4
R1
S3
S2
S1
Temp. Sensor
Pt1000
L
R3
R2
R1
GND
S1
S2
S3
S4
S5
VBus
PW
M
1
PW
M
2
N
R4
V40
L'
VFS
RPS
out
in
Note: 3-port valve normally open - store top (S3)
sted maximum temperature via the valve (R3). The priority
logic effects prior loading of the upper zone of the store.
Domestic hot water afterheating (R4) can be carried out
with a thermostat function (S3).
Adjustment channels
Channel
Description
Page
ARR
System
45
LOAD1 >
Loading 1
45
LOAD2 >
Loading 2
48
COL >
Collector
50
LLOGI >
Loading logic
51
COOL >
Cooling functions
52
AH >
Afterheating option
53
PUMP >
Pump speed
47
MAN >
Manual mode
54
BLPR >
Blocking protection
54
OPARR >
Parallel relay option
55
Adjustment channels
Channel
Description
Page
OHQM >
Heat quantity measurement option
55
GFDS >
Registration Grundfos sensors
55
PRS* >
Pressure monitoring option
57
DATE>
Enter date
57
LANG >
Language
58
UNIT >
Unit
57
OSDC >
SD card option
58
CODE
User code
62
RESET
Factory setting
59
* This channel is only available if the Grundfos sensors have been
registered in the GFDS channel.
** are blocked against each other
Note:
The parameter
LOAD1 refers to
S2, the parameter
LOAD2 2 to S3.