CKG counting scales user’s guide
- -
4
Used to clear the unit weight or an erroneous entry.
Zero
Set the zero point for all subsequent weighing. The display shows zero.
Tare
Tares the scale. Stores the current weight in memory as a tare value, subtracts the tare
value from the weight and shows the results. This is the net weight. Entering a value using
the keypad will store that value as the tare value.
M+
Add the current count to the accumulator. Up to 99 values or full capacity of the weight
display can be added.
MR
To recall the accumulator memory.
Smpl
Used to input the number of items in a sample.
Unit Wt
Used to enter the weight of a sample manually.
PST
or or
Alr
To set the upper limit for the number of items counted. When this upper limit is exceeded
the scale will sound the beeper.
or
To print the results to a PC or printer using the optional RS-232 interface.
SECTION 5 DISPLAYS
5.1 Display map
The scales have three digital displays. The displays show WEIGHT, UNIT WEIGHT and
QUANTITY.