![Citizen CKG-15K Operating Manual Download Page 11](http://html1.mh-extra.com/html/citizen/ckg-15k/ckg-15k_operating-manual_2610320011.webp)
CKG counting scales user’s guide
- - 9
Place a known quantity of items on the scale. After the weight display is stable enter the
quantity of items using the numeric keys followed by
SMPL
key. The number of units will be
displayed on the "Quantity" display and the computed average weight will be shown on the
"Unit Weight" display.
As more items are added to the scale, the weight and the quantity will increase.
If the scale is not stable, the calculation will not be completed. If the weight is below zero,
the quantity display will show negative count.
7.2 Entering a Known Unit Weight
If the unit weight is already known then it is possible to enter that value using the keypad.
Enter the value of the unit weight using the numeric keys followed by pressing the
UNIT WT
key. The "Unit Weight " display will show the value as it was entered.
The sample is then added to the scale and the weight will be displayed as well as the
quantity based upon the unit weight.
7.3 Parts Counting
After the unit weight has been determined or entered it is possible to use the scale for parts
counting. The scale can be tared to account for package weight as discussed in an earlier
section.
After the scale is tared then the items to be counted are added and the "Quantity" display
will show the number of items computed using the weight and the unit weight.
It is possible to increase the accuracy of the unit weight at any time during the counting
process by entering the count displayed then pressing the
SMPL
key. You must be certain
the quantity displayed matches the quantity on the scale before pressing the key. The unit
weight will be adjusted based upon a larger sample quantity. This will give greater accuracy
when counting larger sample sizes.
7.4 Automatic Part Weight Updates
The scales will automatically update the unit weight when a sample equal to less than the
sample already on the platform is added. A beep will be heard when the value is updated. It
is wise to check the quantity is correct when the unit weight has been updated
automatically.
This feature is turned off as soon as the number of items added exceeds the count used as
a sample.
7.5 Count Preset or Check-weighing
Check-weighing (Count Pre-setting) is a procedure to cause an alarm to sound when the
number of items counted on the scale meets or exceeds a number stored in memory by
using the
PST
key.