Citizen CKG-15K Operating Manual Download Page 11

CKG counting scales user’s guide

 

-    -  9

Place a known quantity of items on the scale. After the weight display is stable enter the 
quantity of items using the numeric keys followed by 

SMPL

 key. The number of units will be 

displayed on the "Quantity" display and the computed average weight will be shown on the 
"Unit Weight" display.   
 
As more items are added to the scale, the weight and the quantity will increase. 
 
If the scale is not stable, the calculation will not be completed. If the weight is below zero, 
the quantity display will show negative count. 
 

7.2 Entering a Known Unit Weight 
 

If the unit weight is already known then it is possible to enter that value using the keypad. 
 

 

 
Enter the value of the unit weight using the numeric keys followed by pressing the 

UNIT WT

 

key. The "Unit Weight " display will show the value as it was entered.   
 
The sample is then added to the scale and the weight will be displayed as well as the 
quantity based upon the unit weight. 
 

7.3 Parts Counting 

 
After the unit weight has been determined or entered it is possible to use the scale for parts 
counting. The scale can be tared to account for package weight as discussed in an earlier 
section.   
 
After the scale is tared then the items to be counted are added and the "Quantity" display 
will show the number of items computed using the weight and the unit weight. 
 
It is possible to increase the accuracy of the unit weight at any time during the counting 
process by entering the count displayed then pressing the 

SMPL

 key. You must be certain 

the quantity displayed matches the quantity on the scale before pressing the key. The unit 
weight will be adjusted based upon a larger sample quantity. This will give greater accuracy 
when counting larger sample sizes. 
 

7.4 Automatic Part Weight Updates 
 

The scales will automatically update the unit weight when a sample equal to less than the 
sample already on the platform is added. A beep will be heard when the value is updated. It 
is wise to check the quantity is correct when the unit weight has been updated 
automatically. 
 
This feature is turned off as soon as the number of items added exceeds the count used as 
a sample. 
 

7.5 Count Preset or Check-weighing 

 
Check-weighing (Count Pre-setting) is a procedure to cause an alarm to  sound when the 
number of items counted on the scale meets or exceeds a number stored in memory by 
using the 

PST

 key. 

 

Summary of Contents for CKG-15K

Page 1: ...Table Top Counting Scales CKG Series...

Page 2: ...l t a r e 7 6 2 2 p r e t a r e 7 S E C T I O N 7 P A R T S C O U N T I N G 9 7 1 S e t t i n g u n i t w e i g h t 9 7 2 E n t e r i n g a k n o w n w e i g h t 9 7 3 P a r t s c o u n t i n g 9 7 4...

Page 3: ...have stainless steel weighing platforms on an ABS base assembly All the keypads are sealed color coded membrane switches and the displays are large easy to read liquid crystal type displays LCD The LC...

Page 4: ...ime 2 Seconds typical Operating Temperature 0 C 40 C 32 F 104 F Power supply external 115 230 Vac 110 220Vac 120 240 Vac 50 60Hz Calibration Automatic External Internal counts 600 000 Display 3 x 6 di...

Page 5: ...Do not stack material on the scales when they are not in use 3 2 INSTALLATION of CKG SERIES The CKG Series comes with a stainless steel platform packed separately Place the platform in the locating h...

Page 6: ...M Add the current count to the accumulator Up to 99 values or full capacity of the weight display can be added MR To recall the accumulator memory Smpl Used to input the number of items in a sample Un...

Page 7: ...t large enough to determine an accurate count U Weight or symbol In both cases the scale continues to operate and the indications are to alert the user to a potential problem If a preset count has bee...

Page 8: ...n 4 of power up zero This will usually only be necessary when the platform is empty When the zero point is obtained the Weight display will show the indicator for zero The scale has an automatic rezer...

Page 9: ...r plus all product that was removed The zero indicator will also be on because the platform is back to the same condition it was when the ZERO key was last pressed 6 2 2 Predictable tare This method a...

Page 10: ...putting a known weight using the keypad Weighing a sample to determine the Unit Weight To determine the average weight of the items to be counted it will be necessary to place a known quantity of the...

Page 11: ...e scale can be tared to account for package weight as discussed in an earlier section After the scale is tared then the items to be counted are added and the Quantity display will show the number of i...

Page 12: ...can be set to automatically accumulate totals when a weight is placed on the scale This eliminates the need to press the M key to store values into memory However the M key is still active and can be...

Page 13: ...arity Connector 25 pin d subminiature socket Pin 2 Output Pin 3 Input not used at this time Pin 7 Signal Ground Data Format Normal Output Data Format Memory Recall Print GS 1 234 Kg GS for Gross weigh...

Page 14: ...the Unit Wt key to cycle through the options Press TARE to accept the selection F3 Cnt Displays the A D counts Press Tare to return to menu F4 Au Press the Unit Wt key to show the options Select autom...

Page 15: ...CKG 3000 CKG 6000 CKG 15K CKG 30K Weight 1 zero zero zero Zero Weight 2 1000g 2kg 5kg 10kg Weight 3 3000g 6kg 15kg 30kg 11 2 Normal calibrate Enter the parameter menus by your password default 0000 Wh...

Page 16: ...ENTER key is pressed Weight on the pan when turning the scale on Excessive weight on the pan when zeroing the scale Improper calibration of the scale Damaged load cell Damaged Electronics Err 5 Keybo...

Page 17: ......

Reviews: