Avoid extremes of temperature. Do not place in direct sunlight or near air conditioning 
vents. 
 
Avoid unsuitable tables. The tables or floor must be rigid and not vibrate. Do not place near 
vibrating machinery. 
 
Avoid unstable power sources. Do not use near large users of electricity such as welding 
equipment or large motors. 
 
Avoid high humidity that might cause condensation. Avoid direct contact with water. Do not 
spray or immerse the scales in water. 
 
Avoid air movement such as from fans or opening doors. Do not place near open windows. 
 
Keep the scales clean.   
 
Do not stack material on the scales when they are not in use. 
 

3.2 INSTALLATION of CKG SERIES 

The CKG Series comes with a stainless steel platform packed separately. Place the 
platform in the locating holes on the top cover. Do not press with excessive force as this 
could damage the load cell inside. 
 
Level the scale by adjusting the four feet. The scale should be adjusted such that the 
bubble in the spirit level is in the center of the level and the scale is supported by all four 
feet. If the scale rocks readjust the feet. 
 
Attach the main cable to the connector on the bottom of the scale. The power switch is 
located on the base near the front of the scale. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

SECTION 4 KEY DESCRIPTIONS              

 
0-9,  

•   

Numeric entry keys, used to manually enter a value for tare weights, unit weight, and 
sample size. 
   

CE

  

C

 

Summary of Contents for CKG-15K

Page 1: ...Table Top Counting Scales CKG Series...

Page 2: ...l t a r e 7 6 2 2 p r e t a r e 7 S E C T I O N 7 P A R T S C O U N T I N G 9 7 1 S e t t i n g u n i t w e i g h t 9 7 2 E n t e r i n g a k n o w n w e i g h t 9 7 3 P a r t s c o u n t i n g 9 7 4...

Page 3: ...have stainless steel weighing platforms on an ABS base assembly All the keypads are sealed color coded membrane switches and the displays are large easy to read liquid crystal type displays LCD The LC...

Page 4: ...ime 2 Seconds typical Operating Temperature 0 C 40 C 32 F 104 F Power supply external 115 230 Vac 110 220Vac 120 240 Vac 50 60Hz Calibration Automatic External Internal counts 600 000 Display 3 x 6 di...

Page 5: ...Do not stack material on the scales when they are not in use 3 2 INSTALLATION of CKG SERIES The CKG Series comes with a stainless steel platform packed separately Place the platform in the locating h...

Page 6: ...M Add the current count to the accumulator Up to 99 values or full capacity of the weight display can be added MR To recall the accumulator memory Smpl Used to input the number of items in a sample Un...

Page 7: ...t large enough to determine an accurate count U Weight or symbol In both cases the scale continues to operate and the indications are to alert the user to a potential problem If a preset count has bee...

Page 8: ...n 4 of power up zero This will usually only be necessary when the platform is empty When the zero point is obtained the Weight display will show the indicator for zero The scale has an automatic rezer...

Page 9: ...r plus all product that was removed The zero indicator will also be on because the platform is back to the same condition it was when the ZERO key was last pressed 6 2 2 Predictable tare This method a...

Page 10: ...putting a known weight using the keypad Weighing a sample to determine the Unit Weight To determine the average weight of the items to be counted it will be necessary to place a known quantity of the...

Page 11: ...e scale can be tared to account for package weight as discussed in an earlier section After the scale is tared then the items to be counted are added and the Quantity display will show the number of i...

Page 12: ...can be set to automatically accumulate totals when a weight is placed on the scale This eliminates the need to press the M key to store values into memory However the M key is still active and can be...

Page 13: ...arity Connector 25 pin d subminiature socket Pin 2 Output Pin 3 Input not used at this time Pin 7 Signal Ground Data Format Normal Output Data Format Memory Recall Print GS 1 234 Kg GS for Gross weigh...

Page 14: ...the Unit Wt key to cycle through the options Press TARE to accept the selection F3 Cnt Displays the A D counts Press Tare to return to menu F4 Au Press the Unit Wt key to show the options Select autom...

Page 15: ...CKG 3000 CKG 6000 CKG 15K CKG 30K Weight 1 zero zero zero Zero Weight 2 1000g 2kg 5kg 10kg Weight 3 3000g 6kg 15kg 30kg 11 2 Normal calibrate Enter the parameter menus by your password default 0000 Wh...

Page 16: ...ENTER key is pressed Weight on the pan when turning the scale on Excessive weight on the pan when zeroing the scale Improper calibration of the scale Damaged load cell Damaged Electronics Err 5 Keybo...

Page 17: ......

Reviews: