Warranty 

- The usual Warranty period granted on our devices cover 12 
months after the delivery – the date of Invoice being decisive. 
- Any cases of consequential damage due to the failure of the 
hot air generators and boilers during operation 
will be excluded. 
 
WARRANTY IS VOID IF: 
-     Burner is not maintained in accordance with maintenance 
requirements. 

-

Wiring is not in accordance with circuit diagram 

-

EL fuel oil according to the DIN Standard No.51 603-1 is 
used at temperature below +4 C or if winter diesel is used 
below stipulated temperatures. (IT IS STRICTLY PROHIBITED 
TO ADD ANY PETROL!!!). The Burners must not be modified 
or tampered with under circumstances, and repair work 
must be carried out by a specialist. 

-

Without the proof of a technically correct delivery, any 
warranties from the side of the Company CITERM will 
lapse. 

-

If the pump pressure is set at a higher value, the motor will 
be overheated and may be damaged, excluding any 
warranties. 

-

The Warranty will only be granted if a regular servicing is 
carried out at least once a year in accordance with the 
CITERM operating instructions.  

Summary of Contents for G1p

Page 1: ...MULTIFUEL oil burners Complyng with EMC 89 336 EC LV 73 23 EC 1...

Page 2: ...trode adjustment 14 15 Burner pump 15 16 16 Maintenance 17 20 17 Parts drawing 21 18 Parts list 22 19 Main construction parts 23 20 Conformity declaration 24 21 Warranty 25 Read the operation instruct...

Page 3: ...ne paint thinners or non approved fluids Adequate ventilation must be provided in any enclosure where storage tanks pump or accessories are installed Identical to any gas or oil burning appliance with...

Page 4: ...s the regulated temperature is reached An additional overheat thermostat prevents overheating A special nozzle draws the fuel by using the passing compressed air which serves as primary air for the co...

Page 5: ...5 JUNIOR Dimensiones...

Page 6: ...6 Dimensions Gp G1p G2p G2p G3p G3p...

Page 7: ...7 Dimensions Boiler location Air oil flow schematic...

Page 8: ...require higher air pressures Oil pump The oil pumps serve as delivery units pumping oil into the burner tank The atomization of the oil is not dependent on the oil pressure Do not increase oil pressur...

Page 9: ...be rigidly fastened in place in workmanlike manner NOTE Care must be exercised to ensure leak free connections Flue connection Important condition for perfect operation of the furnace is a correctly d...

Page 10: ...ng the preventilation time after the safety time The control device may only be plugged in or unplugged if the main switch is in the OFF position or if the 7 pin plug connector is disconnected because...

Page 11: ...ostat When setting burner for the first time into operation fill burner tank with combustion manual Normal oil level is 50mm from the top If you fill it more overflow switch will turn off burner Secon...

Page 12: ...12 Wiring diagram...

Page 13: ...13 Troubleshooting...

Page 14: ...14 Electrode adjustment It is important to clean electrodes and flame ring monthly to achieve problem free start JUNIOR...

Page 15: ...15 Burner pump...

Page 16: ...16 Burner pump...

Page 17: ...nk Screw back vacuum port screw Unscrew bleed port Turn the burner on When oil arrive close bleed port Maintenance SUPPLY LINES Read this section carefully before installing any supply lines Since a s...

Page 18: ...The quantity can be determined by using water indication paste and a gauging rod Clean the photocell Clean the ignition electrodes and flame ring and blow out the nozzle with compressed air check the...

Page 19: ...19 Remote pump Instalation 1 Floater 2 Strainer 3 Flexible oil line 4 Remote pump 5 Oil in the storage tank 6 Burner 7 Combustion chamber 8 Boiler Remote pump 130W Suction unit...

Page 20: ...m from the top of the heater Ceramic fibre necessary for all burners when used with steel boilers with large combustion chamber or cast iron boilers with a vertical rear panel in the combustion chambe...

Page 21: ...21 Part droving...

Page 22: ...tube 21 Flame ring 22 Ignition electrode 23 HT cable 24 Burner tank 25 Heating cartridge 26 Floater 27 Copper pipe 1 28 Burner body lid 29 Overflow tank 30 Contact switch 31 Oil pipe 32 Oil pump 33 So...

Page 23: ...lator Overheat thermostat Overflow tank Float switch Burner tank Drain tap Oil pump Secondary air regulator Control box Motor Compressed air connection Primary air pressure regulator Solenoid valve Pr...

Page 24: ...73 23 EC in connection with VDE 0700 part 1 version 04 88 and DIN VDE 0722 version 04 83 Electrical safety according to DIN EN 50 165 2003 and EN 60335 1 2003 Electromagnetic compatibility according...

Page 25: ...603 1 is used at temperature below 4 C or if winter diesel is used below stipulated temperatures IT IS STRICTLY PROHIBITED TO ADD ANY PETROL The Burners must not be modified or tampered with under cir...

Reviews: