20
Maintenance
Be careful when adjusting
double switch!
Normal fuel level is 50mm
from the top of the heater.
Safety contact must trigger
if level raise to 25mm from
the top of the heater.
Ceramic fibre – necessary for all burners when used with
steel boilers with large combustion chamber or cast-iron
boilers with a vertical rear panel in the combustion chamber.
Ceramic fibre will prevent making deposits of unburned oil
at the bottom of the boiler.
Drain tap
It is necessary to open drain tap
To release settled water.