Page 14
GENERAL
Floor Space ............................................ 64” (1626 mm) Deep x 54”
SPECIFICATIONS
(1372 mm) Wide x 96”
FOR 150 lb. DRYERS
(2439 mm) High
Doors .................................................... 31-1/4” (794 mm) Diameter
Basket Size .......................................... 50” (1270 mm) Diameter x
42” (1067 mm) Deep
Basket Capacity (Dry Weight) ........ 150 lbs. (68.0 kg) Dryweight
Basket Motor ...................................... 1-1/2 HP (1.12 kW)
Fan Motor ............................................ 1-1/2 HP (1.12 kW)
Basket RPM (Reversing) ................. 28 - 3.2 reversals per min.
(Non-Reversing) ................................. 30
Exhaust Duct ..................................... 12” (305 mm) Diameter
Maximum Air Displacement ........... 2,250 cfm (3825 m
3
/h)
Recommended Operating ................ 1,900 - 2,100 cfm
Range
(3230 - 3570 m
3
/h)
Net Weight
(Gas) ...............................
1,740 lbs. (789 kg) approx.
(Steam) .................................................
1,754 lbs. (796 kg) approx.
Shipping Weight
(Gas) .....................
1,890 lbs. (857 kg) approx.
(Steam) .................................................
1,944 lbs. (882 kg) approx.
Export Shipping Dimensions .......... 104” H (2642 mm) x 60” W
(1524 mm) x 74” L (1880 mm)
Export Crate
(Gas) ............................
254.5 ft³ (7.21 m³)
(Steam) .................................................
261.1 ft³ (7.40 m³)
Load Weight on Floor Area ............. .69 lb./sq. in. (48.5 lb./sq. in.)
BTU Input Rating *
(see next page) ...............
370,000 Btu per hour
(93,240 kcal/h)
(Nat., Mixed, Mfg., Butane and
Propane Gases)
Steam Consumption ......................... 12.5 bhp - 419 lbs.
(418,187 Btu/h)
Operating Steam Pressure .............. 100 psi (6.9 bar) max
Gas Supply .......................................... 1” (3 mm) Pipe Connection
Manifold Pressure ............................. 3.5”w.c. (8.7 mbar) (Natural Gas)
11”w.c. (27 mbar) (LP Gas)
Electric Ignition ................................. Direct Spark Ignition System
DRYER SPECIFICATIONS
Summary of Contents for HD170
Page 12: ...Page 12 GAS DRYER DIMENSIONS ...
Page 13: ...Page 13 STEAM DRYER DIMENSIONS ...
Page 18: ...Page 18 GAS PIPING INSTALLATION ILLUSTRATION ...
Page 26: ...Page 26 DRYER INSTALLATION WITH MULTIPLE EXHAUST ILLUSTRATION ...
Page 33: ...Page 33 OPERATING INSTRUCTIONS TWO TIMER MODELS ...
Page 41: ...Page 41 DIRECT SPARK IGNITION OPERATION FLOW CHART ...
Page 43: ...Page 43 BURNER AIR INLET ADJUSTMENT BURNER AIR INLET ADJUSTMENT ...
Page 44: ...Page 44 BASKET ALIGNMENT FOR DRYERS WITH TM200 GEAR REDUCER ...
Page 53: ...Page 53 REAR VIEW TM200 GEAR REDUCER See following page for partnumbers ToGearM otor ...
Page 55: ...Page 55 REAR VIEW GEAR MOTOR See following page for partnumbers ToGearM otor ToFanM otor ...
Page 75: ...Page 75 ...