APPPENDIX A:
Voice and fax boards
145
Hardware settings
Do the following procedure as you install fax boards.
To set switch block SW1
The switch block SW1 settings determine the fax ports’ I/O
addresses.
The CPi/200 board contains two fax ports. Depending on the
configuration of the Unity server, you can install up to two
CPi/200 boards.
Set the SW1 switches on each board as shown below.
LED status indicators
There are two LED status indicators for each fax port. The fol-
lowing table describes the meaning of the status indicators.
SW1
First board
Ports 0–1
First board
Ports 4–5
Color
Lit
Unlit
Blinking
Green
Port is off hook
Port is on hook
---
Amber
Board is
operational
Board is not
operational
Board configuration
problem
On
Off
1 2 3
On
Off
1 2 3