S e n d d o c u m e n t c o m m e n t s t o u c s - d o c f e e d b a c k @ c i s c o . c o m
2-25
Cisco UCS 6100 Series Fabric Interconnect Hardware Installation Guide
OL-20036-02
Chapter 2 Installing the Cisco UCS 6100 Series Fabric Interconnect
Replacing or Installing Components
Note
You can replace a faulty power supply while the system is operating provided the other power supply is
functioning.
This section includes the following topics:
•
Removing a Power Supply, page 2-25
•
Installing a Power Supply, page 2-26
Removing a Power Supply
Caution
If you are using the Cisco UCS 6100 Series Fabric Interconnect with one power supply, removing the
power supply causes the system to shut down. If you are using two power supplies and you remove one
of them, the system continues to operate.
To remove a power supply, follow these steps:
Step 1
Ensure that the system (earth) ground connection has been made. For ground connection instructions,
see the
“Grounding the System” section on page 2-11
.
Step 2
Grasp the power supply handle with your left hand.