xConfiguration SystemUnit ContactInfo Type
Choose which type of contact information to show in the status field in the upper left corner of the
main display and Touch controller. The information can also be read with the command xStatus
SystemUnit ContactInfo.
Requires user role:
ADMIN
Value space:
<Auto/None/IPv4/IPv6/H323Id/E164Alias/H320Number/SipUri/SystemName/
DisplayName>
Auto:
Show the address which another system can dial to reach this system. The address depends
on the default call protocol and system registration.
None:
Do not show any contact information in the status field.
IPv4:
Show the IPv4 address as contact information.
IPv6:
Show the IPv6 address as contact information.
H323Id:
Show the H.323 ID as contact information (see the H323 Profile [1..1] H323Alias ID
setting).
E164Alias:
Show the H.323 E164 Alias as contact information (see the H323 Profile [1..1] H323Alias
E164 setting).
H320Number:
Show the H.320 number as contact information (only applicable if connected to a
Cisco TelePresence ISDN Link gateway).
SipUri:
Show the SIP URI as contact information (see the SIP Profile [1..1] URI setting).
SystemName:
Show the system name as contact information (see the SystemUnit Name setting).
DisplayName:
Show the display name as contact information (see the SIP Profile [1..1] DisplayName
setting).
Example:
xConfiguration SystemUnit ContactInfo Type: Auto
xConfiguration SystemUnit IrSensor
The codec has a short-range IR sensor underneath the power button. It may be used with the
remote control, but it is not intended for regular operation. It should be used only when required for
troubleshooting or system recovery. In regular operation, the IR sensor on the camera should be
used with the remote control, refer to the Cameras Camera [1] setting.
Requires user role:
ADMIN
Value space:
<Auto/Off/On>
Auto:
The IR sensor of the codec is disabled whenever the IR sensor of the camera is enabled.
The IR sensor of the codec is enabled only if the IR sensor of the camera is disabled.
Off:
Disable the IR sensor of the codec.
On:
Enable the IR sensor of the codec.
Example:
xConfiguration SystemUnit IrSensor: Auto
Time configuration
xConfiguration Time TimeFormat
Set the time format.
Requires user role:
USER
Value space:
<24H/12H>
24H:
Set the time format to 24 hours.
12H:
Set the time format to 12 hours (AM/PM).
Example:
xConfiguration Time TimeFormat: 24H
xConfiguration Time DateFormat
Set the date format.
Requires user role:
USER
Value space:
<DD_MM_YY/MM_DD_YY/YY_MM_DD>
DD_MM_YY:
The date January 30th 2010 will be displayed: 30.01.10
MM_DD_YY:
The date January 30th 2010 will be displayed: 01.30.10
YY_MM_DD:
The date January 30th 2010 will be displayed: 10.01.30
Example:
xConfiguration Time DateFormat: DD _ MM _ YY
xConfiguration Time Zone
This has been replaced with the Time OlsonZone setting as of software version TC7.2.