Installing the Second Row Table (IX5200 Only)
Page 124
© 2015 Cisco Systems, Inc. All rights reserved.
Required Parts Cont’d
Tabletops (700-45242-xx far right, 700-45239-xx far left, 700-103970-xx second
from right, 700-103971-xx second from left, 700-45241-xx mid-right, 700-45240-
xx mid-left)
20x Biscuit joiner, 700-23909-xx
10x Half moon bolt, M6X80MM, 51-6068-xx
10x Joint plate, 700-23345-xx
102x M8x16mm screws, black 69-2802-xx
Mute button covers (3x 700-45426-xx, 3x 700-45427-xx)
24x M4x10mm black screws 69-2817-xx
14x leg PET panels (2x outside panels 700-43424-xx, 6x right inside panels 700-
43426-xx, 6x left inside panels 700-43427-xx
6x front panel covers (3x 700-43502-xx, 3x 700-43005-xx
Velcro cable straps 52-0449-xx as needed
Required Tools
•
#4 and #2 Philips screwdrivers
•
7mm & 10mm socket
•
7mm Allen driver or wrench
•
10mm ratcheting wrench or socket
•
Laser level
Required Cables
69-2833-xx cabling kit, includes the following subkits:
69-2670-xx, includes 2x Ethernet cables 37-1558-xx and 37-1534-xx,
EX2
and
EX3
69-2672-xx, includes 13x Ethernet cables 37-1558-xx
C7-C18, CX2
69-2675-xx (mic bar and mute button), includes:
•
2x DisplayPort-to-DisplayPort cables, 12 meter, 37-1541-xx,
MC2
and
MC3
•
12x Mini-DisplayPort-to-Mini-DisplayPort cables, 2.6 meters, 37-1542-xx,
A7-
A18
69-2677-xx, includes 3x Jumper Cord, 2 meter, 37-0994-xx
Required Parts
7x Table legs (1x far left leg 800-44198-xx, 1x far right leg 800-44197-xx, 5X
inside legs 800-44200-xx)
21x M8x16MM screws 69-2802-xx
6x each Back row cable management assembly, left and right (3x 800-42717-
xx and 3x 800-42715-xx)
2x switches WS-C2960C-8PC-L
4x switch bracket 700-44758-xx
2x microphone connector (MCs) 800-40951-xx
2x Power distribution units (PDUs) 74-8655-xx
12x M6 nuts 49-100235-xx
4x #10-32 pan head screws 69-2818-xx
7x Metal trim pieces (700-103477-xx left corner, 700-103476-xx right corner,
700-45431-xx outside-left, outside right, and center, 700-45430-xx inside-left
and inside-right)
Ethernet/Power modules:
•
12x Power/Ethernet connectivity modules (part varies by country)
•
7x Power/Ethernet connectivity cover 700-47772-xx
•
2x Power/Ethernet connectivity blanking plates 700-45421-xx
•
28x #4-40 nuts for power/Ethernet connectivity brackets
62x M4x12mm screws 69-2801-xx
30x M4 countersunk screw 69-2817-xx
1x downspout kit (includes short round piece 700-46612-xx, long flat piece
700-46613-xx, 3x M4x10 screws 69-2817-xx, and 3x M6x10mm screws 69-
2803-xx)
6x Mute button assembly 74-12200-xx
12x M6x10mm screws 69-2803-xx
3x Microphone bars 74-12199-xx
*
3x Turnaround microphone bars 74-12552-xx
*
*
The packaging includes the mic bar and the center cap. Do
not
throw the
small round caps away.
Installing the Second Row Table (IX5200 Only)
Summary of Contents for TelePresence IX5000
Page 71: ...Installing Endpoint Structure Cables 2015 Cisco Systems Inc All rights reserved Page 71 ...
Page 72: ...Installing Endpoint Structure Cables Page 72 2015 Cisco Systems Inc All rights reserved ...
Page 185: ...Cable Routing Diagrams 2015 Cisco Systems Inc All rights reserved Page 185 ...
Page 186: ...Cable Routing Diagrams Page 186 2015 Cisco Systems Inc All rights reserved ...