Chapter 5 Connecting the Management Interfaces and Performing Initial System Configuration
Initial System Configuration
Cisco SCE 2000 4/8xFE Installation and Configuration Guide
OL-7826-05
5-21
Enter Physically connected link:
0- link-0
1- link-1
Enter your choice [0]:
Step 5
Specify the
SCE 2000
priority.
•
To specify
Primary
, press
Enter
.
•
To specify
Secondary
, type
2
and press
Enter
.
Enter
SCE 2000
priority:
1- primary
2- secondary
Enter your choice [1]:
Step 6
Specify the On-failure link behavior.
•
To specify
Bypass
, press
Enter
.
•
To specify
Cutoff
, type
2
and press
Enter
.
Enter On-failure behavior:
1- bypass
2- cutoff
Enter your choice [1]:
Step 7
Specify the status of the
SCE 2000
after abnormal boot.
•
To specify
Operational
status after abnormal boot, press
Enter
.
•
To specify
Not-Operational
status after abnormal boot, type
2
and press
Enter
.
Enter admin status of the SCE after abnormal boot:
1- Operational
2- Not-Operational
Enter your choice [1]:
The following examples present the procedure for configuring the topology-related parameters for
various topologies.
E
XAMPLE
1:
Following is a sample topology configuration for a non-redundant topology using an external
switch, that is, a single
SCE 2000
connected in receive-only connection mode, to one or two FE
links
Would you like to enter the Topology configuration menu? [no]:
y
Would you like to enter the Topology configuration menu? [no]:
y
Enter Connection mode:
1- inline
2- receive-only
Enter your choice [1]:
2
Is this a cascade deployment? [no]:
no
Enter admin status of the SCE after abnormal boot:
1- Operational
2- Not-Operational
Enter your choice [1]:
1
Data collection for the system configuration is completed.
All other parameter values are automatically assigned by the system.