4-13
Cisco ONS 15200 Installation, Setup, and Test Manual
78-13765-01
Chapter 4 Turn Up and Test
Step 18
Test A-side protected channels and all non-protected channels:
a.
Break the connection on the B-side LM. All of the protected channels should have the Active light
on the A side illuminated and no LED illuminated on the B side. Unprotected channels should have
either the Active light on the A side illuminated or no lights illuminated. Bit errors are caused by a
broken connection.
b.
Reconnect the B-side jumper and ensure that the A-side Active LED remains illuminated on
protected CLIP modules and that all unprotected CLIP modules are active on either the A side or B
side.
c.
Clear all errors on the test set and run the BER test error-free for 15 minutes. Complete Step
in
Step 19
Test B-side protected channels and all non-protected channels:
a.
Break the connection on the A-side LM. All of the protected channels should have the B-side Active
LED illuminated and no LED illuminated on the A side. Unprotected channels should either have
the B-side Active LED illuminated or no LED illuminated. Bit errors are caused by a broken
connection.
b.
Reconnect the A-side jumper cable and verify the following: the B-side Active LED remains lit on
the protected CLIP modules, the A-side Standby LED illuminates, and all unprotected CLIP
modules are Active on either the B side or the A side.
c.
Clear all errors on the test set and run the BER test error-free for 15 minutes. Complete Step
in
Step 20
Return the CLIP switchmode setting to the original setting (
4.4 ONS 15201 SCU Turn Up and Test
Use the following procedures to turn up and test the ONS 15201 SCU.
Procedure: Initialize the ONS 15201 SCU
Step 1
Connect a laptop to the management access (MA) port located on the ONS 15201 SCU using the PCCAN
cable, CAN interface cable, and the PCMCIA LAPcan board (
). For more information, refer