3-49
Cisco ONS 15200 Installation, Setup, and Test Manual
78-13765-01
Chapter 3 Installation
Step 10
Remove the dust plugs located on the inside of the SCU SC-to-SC adapters.
Step 11
Perform the following for each SC connector on the CFM fiber:
a.
Remove the dust cap from the SC connector on the CFM fiber. Do not remove the dust cap on the
MU connector of the CFM fiber.
b.
Clean and inspect each SC connector on the fiber.
Step 12
Connect the CFM fiber to the A- and B-side SC-to-SC adapters in accordance with the labels on the
cables.
shows a CFM for an unprotected channel;
shows a CFM for a protected
channel.
through
show the connection information for each configuration.
Figure 3-38 CFM for an unprotected channel (100/0 or 0/100)
Figure 3-39 CFM for a protected channel (90/10, 10/90, or 50/50)
67747
A
67748
B
A