Status
Color
LED
The port is active (the link is connected and active).
Green
Link (for
each port)
The port is disabled by the operator or is not initializing.
Orange
The port is faulty and disabled.
Flashing orange
The port is not active or the link is not connected.
Off
Power Supply LEDs
Depending on the power supply (AC, DC and HVAC/HVDC power supplies), there are 1 or 2 input LEDs. The Output, Fault, and
ID LEDs have the same function for the AC, DC and HVAC/HVDC power supply units.
Status
Color
LED
The AC, HVAC/HVDC, or DC input voltage is within the valid range.
Green
Input 1
The AC, HVAC/HVDC, or DC input voltage is outside the valid range.
Off
The DC input voltage is within the valid range.
Green
Input 2
(available
only on DC
power
supply
units)
The DC input voltage is outside the valid range.
Off
The AC or DC output power is within the valid range.
Green
Output
The AC or DC output power is outside the valid range.
Off
The AC or DC output voltage and power supply unit tests are okay.
Off
Fault
Self-diagnostic tests have failed or another power supply failure has occurred.
Flasing red
The operator has activated this LED to identify this module in the chassis.
Flashing blue
ID
This module is not being identified.
off
Cisco Nexus 7702 Hardware Installation Guide
126
LEDs
Power Supply LEDs