Block Checksum
: 0x31e
Serial Number
: JAE191106QG
Displaying Environmental Information for a Switch
You can display all of the environment-related switch information by using the
show environment
command.
Enter the
show environment
command.
Example:
switch#
show environment
Power Supply:
Voltage: 50 Volts
Power
Actual
Total
Supply
Model
Output
Capacity
Status
(Watts )
(Watts )
-------
-------------------
-----------
-----------
--------------
1
N7K-AC-3KW
251 W
3000 W
Ok
2
N77-AC-3KW
245 W
3000 W
Ok
Actual
Power
Module
Model
Draw
Allocated
Status
(Watts )
(Watts )
-------
-------------------
-----------
-----------
--------------
1
N77-F348XP-23
328 W
480 W
Powered-Up
2
N77-SUP2E
131 W
265 W
Powered-Up
fan1
N77-C7702-FAN
39 W
300 W
Powered-Up
N/A - Per module power not available
Power Usage Summary:
--------------------
Power Supply redundancy mode (configured)
PS-Redundant
Power Supply redundancy mode (operational)
PS-Redundant
Total Power Capacity (based on configured mode)
3000 W
Total Power of all Inputs (cumulative)
6000 W
Total Power Output (actual draw)
496 W
Total Power Allocated (budget)
1045 W
Total Power Available for additional modules
1955 W
Clock:
----------------------------------------------------------
Clock
Model
Hw
Status
----------------------------------------------------------
A
Clock Module
--
NotSupported/None
B
Clock Module
--
NotSupported/None
Fan:
------------------------------------------------------
Fan
Model
Hw
Status
------------------------------------------------------
Fan1(sys_fan1)
N77-C7702-FAN
0.0
Ok
Fan_in_PS1
--
--
Ok
Fan_in_PS2
--
--
Ok
Fan Zone Speed: Zone 1: 0x79
Cisco Nexus 7702 Hardware Installation Guide
43
Managing the Switch
Displaying Environmental Information for a Switch