5-91
Cisco MGX 8800/8900 Series Hardware Installation Guide
Releases 2 - 5.2, Part Number OL-4545-01, Rev. H0, May 2006
Chapter 5
Installing the Cisco MGX Switch or Gateway
Installing the MGX 8950 Switch
Warning
Do not touch the power supply when the power cord is connected. For systems with a power switch,
line voltages are present within the power supply even when the power switch is off and if the power
cord is connected. For systems without a power switch, line voltages are present within the power
supply when the power cord is connected.
Statement 4
Connect AC Power to the Switch
To connect AC power to the MGX 8950 switch, use AC power cords with the following types of AC wall
plugs:
•
30A NEMA L620, 3-prong plug (North America), shown in
Figure 5-57
.
Figure 5-57
AC Power Cable (North America)
•
30A IEC 309 plug
(Europe, Australia, New Zealand), shown in
Figure 5-58
.
Figure 5-58
AC Power Cable IEC 309 Plug (International)
Complete the following steps to connect a North American AC power cord to the switch:
Step 1
Insert the female connector into the AC receptacle on the AC power supply tray.
Step 2
Twist the plug to the right to secure it.
Step 3
Insert the other end of the power cable into the wall outlet.
Step 4
Repeat
Step 1
through
Step 3
to connect the other AC cable to the remaining AC power supply tray.
Complete the following steps to connect an international AC power cable to the switch:
Step 1
Insert the female connector into the AC power supply tray receptacle, as shown in
Figure 5-59
.
44147x
To power supply
To AC outlet
75422
To AC outlet