Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/Hr (36°F/Hr).
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
Operating
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
Non-operating
5 to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature, non-
condensing.
Altitude
Altitude
Altitude
Altitude
Operating
3050 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500 ft/min).
Vibration
Vibration
Vibration
Vibration
Operating
Operating
Operating
Operating
1 G, 10-500 Hz, 60 minutes per axis
Non-operating
Non-operating
Non-operating
Non-operating
2 G, 10-500 Hz, 30 minutes
Shock
Shock
Shock
Shock
Operating
Operating
Operating
Operating
Half-sine-wave shock, 40 G, 2 ms duration, in each direction of three
mutually perpendicular axes.
Non-operating
Non-operating
Non-operating
Non-operating
Half-sine-wave shock, 140 G, 2 ms duration, in each direction of three
mutually perpendicular axes; and square-wave shock up to 80 G, 180
inches/s velocity change, in each direction of three mutually perpendicular
axes.
EMI
EMI
EMI
EMI
CFR 47 Subpart B of Part 15 of the FCC Rules, Class A level
CISPR22 Class A
EN55022 Class A
VCCI Class A ITE
AS/NZS 3548 Class A
CNS 13438 Class A
EMC Directive (89/336/EEC) for CE Marking in European Union
Safety
Safety
Safety
Safety
Underwriters Laboratories, UL60950
Canadian Standards Association, CSA60950
TUV Rheinland of North America, EN60950
Nemko, EN60950
Low Voltage Directive (73/23/EEC) for CE Marking in European Union
Fibre Channel Standards
Fibre Channel Standards
Fibre Channel Standards
Fibre Channel Standards
And Revisions
And Revisions
And Revisions
And Revisions
FC-PH, Revision 4.3
FC-PH-2, Revision 7.4
FC-PH-3, Revision 9.4
FC-GS-2, Revision 5.3
FC-GS-3, Revision 7.01
FC-FLA, Revision 2.7
FC-FG, Revision 3.5
FC-SW-2, Revision 5.3
FC-AL, Revision 4.5
FC-AL-2, Revision 7.0
FC-PLDA, Revision 2.1
FC-VI, Revision 1.61
FCP, Revision 12
FCP-2, Revision 7
FC-SB-2, Revision 2.1
QuickSpecs
Cisco MDS 9124e Fabric Switch for HP c-Class
Cisco MDS 9124e Fabric Switch for HP c-Class
Cisco MDS 9124e Fabric Switch for HP c-Class
Cisco MDS 9124e Fabric Switch for HP c-Class
BladeSystem
BladeSystem
BladeSystem
BladeSystem
Technical Specifications
DA - 12653 Worldwide — Version 12 — June 8, 2011
Page 13