A P P E N D I X
A
Technical Specifications
•
C9606R Switch Chassis Specifications, on page 91
•
Power Supply Specifications, on page 93
•
Chassis and Module Power and Heat Values, on page 95
•
Weight Specifications, on page 96
C9606R Switch Chassis Specifications
Table 5: Physical Specifications of the Chassis
Specification
Item
13.95 X 17.4 X 16.1 inches (35.43 x 44.2 x 40.9 cms)
Dimensions (H x W x D)
8 RU
Rack units (RU
)
63.0 lb (31.31 kg)
Weight (Chassis with two AC power supplies and fan
tray)
4
The chassis height is measured in rack units (RU or just U), where 1 RU or 1 U equals 1.75 in (44.45
mm).
Table 6: Environmental Specifications of the Chassis
Specification
Item
• 23° to 113°F (-5 to +45ºC), up to 6,000 feet (1800 m)
• 23° to 104°F (-5 to +40ºC), up to 10,000 feet (3000 m)
Ambient temperature and
altitude for normal
operations
• 23°F to 122°F (-5ºC to +50ºC), up to 6,000 feet (1800 m)
• 23°F to 122°F (-5ºC to +45ºC), up to 10,000 feet (3000 m)
Ambient temperature and
altitude for short-term
exceptional conditions
-40° to 167°F (-40° to 75°C)
Nonoperating and storage
temperature
Cisco Catalyst 9600 Series Switches Hardware Installation Guide
91