ACLMGR Messages
Error Message
ACLMGR-2-NOMAP: Cannot create ACL Manager data structures for VLAN Map
[chars].
Explanation
The ACL manager could not allocate the data structures needed to describe a VLAN
map into a form that can be loaded into hardware. This error is most likely caused by lack of free
memory. [chars] is the VLAN map name.
Recommended Action
Reduce other system activity to ease memory demands.
Error Message
ACLMGR-2-NOVLB: Cannot create memory block for VLAN [dec].
Explanation
The ACL manager could not save per-VLAN information needed for its correct
operation. Some per-interface features, such as access groups or VLAN maps, will not be configured
correctly. [dec] is the VLAN ID.
Recommended Action
Use a less complicated configuration that requires less memory.