Wall Mounting the AP with Horizontal Kit
The mounting wall, attaching screws, and wall anchors must support the least 50-lb (22.7-kg) static weight.
The installer must supply proper screws and anchors in accordance with local codes.
Caution
Before you begin
Ensure that you have the following materials before beginning to mount the AP horizontally to a wall:
Table 9: Materials Needed for Mounting the AP using AIR-MNT-HORZ1= Kit
Supplied in the
Kit?
Materials Required
Yes
Wall/Pole Mount L-Bracket
Yes
Solar Shield Cover
Yes
(4) M6 x 12-mm Hex-head Bolts
Yes
(2) Adjustable Band Clamps 2 to 5 inch (51 to 127 mm) Dia
Yes
(4) 8-32 x 0.62” Phillips Pan Head Screw
No
(4) wall screws and anchors (specified for wall material)
No
Drill bit for wall anchors
No
10–mm box-end wrench or socket set
No
Phillips Screwdriver
Procedure
Step 1
Use the mounting bracket as a template to mark four screw hole locations on the mounting wall. See
63: Wall mount L-bracket screw hole dimensions, on page 56
for the mounting bracket screw hole locations
and dimensions. See
Figure 64: L-bracket AP mount dimensions, on page 56
for dimensions of the mounting
L-bracket.
Cisco Catalyst 9124AX Series Outdoor Access Point Hardware Installation Guide
55
Installation Overview
Wall Mounting the AP with Horizontal Kit