A-12
Catalyst 4500 E-Series Switches Installation Guide
OL-13972-02
Appendix A Power Supply Specifications
1400 W AC-Input Power Supply
Table A-8
list the 1400 W AC-input power supply LEDs and their meanings.
Branch circuit requirement
Each chassis power supply should have its own dedicated, fused-branch
circuit:
•
For North America—15 A or 20 A
•
For International—Circuits sized to local and national codes
•
All Catalyst 4500 E-series AC-input power supplies require
single-phase source AC.
•
All AC power supply inputs are fully isolated.
–
Source AC can be out of phase between multiple power supplies
in the same chassis, which means that PS1 can be operating
from phase A and PS2 can be operating from phase B.
–
For high-line operation, the power supply operates with the hot
conductor wired to a source AC phase and the neutral conductor
wired either to ground or to another source AC phase as long as
the net input voltage is in the range of 170 to 264 VAC.
–
Source AC can be out of phase between AC inputs on power
supplies that are equipped with multiple AC inputs, which
means that power cord 1 can be plugged into phase A and
power cord 2 can be plugged into phase B.
Power supply output
2473 W maximum
1360 W + 40 W redundant mode (data)
Power supply output (AC
supply)
113.4 A @ +12 V
12.2 A @ +3.3 V (data)
Output holdup time
20 ms minimum
Max heat dissipation
1048 BTUs/hr
Maximum kVA rating
1.76 kVA
Minimum software
requirement
Cisco IOS Release 12.2(18)EW
Power over Ethernet
Not supported
1
1.
A Catalyst 4503-E with a Catalyst 4500 E-series Supervisor Engine II-Plus TS and a 1400W AC power supply provides 158.4
W of PoE to ports on the supervisor engine. Switching modules in other slots will not be able to provide PoE.
Table A-7
1400 W AC-Input Power Supply Specifications (continued)
Item
Specification