5-8
Catalyst 4500 E-Series Switches Installation Guide
OL-13972-02
Chapter 5 Troubleshooting
Troubleshooting Switching Modules
•
The output-fail LED on the power supplies are red and no power is delivered to the chassis. The
other LEDs on the power supply are green.
•
The Status LEDs on the switching modules and the supervisor engine are flashing green.
•
CPU Utilization LEDs are flashing green or off.
If you observe these conditions, contact the Cisco TAC for assistance in ordering replacement
redundancy modules and a clock.
Troubleshooting Switching Modules
Each switching module has one LED labeled STATUS that provides information about the module and
one numbered LED labeled LINK for each port on the module.
Figure 5-1
shows the Gigabit Ethernet
port and status LEDs.
Figure 5-2
shows the 10/100BASE-T port LEDs.
Table 5-1
describes the
switching module LEDs and their expected behavior.
Figure 5-1
Gigabit Ethernet Port and Status LEDs
Figure 5-2
10/100BASE-T Port LEDs
1
26854
1000BASE-X SWITCHING MODULE
STATUS
2
3
WS-X4306-GB GIGABIT ETHERNET
Table 5-1
Switching Module LEDs
LED
Color/State Description
STATUS
Indicates the results of a series of self-tests and
diagnostic tests performed by the switch.
Green
All the tests pass.
Red
A test other than an individual port test failed.
Orange
System boot, self-test diagnostics running, or the
module is disabled.
LINK
Indicates the status of the port.
Green
The port is operational (a signal is detected).
17407
STATUS
4
1
2
3
4
5
5
6
6
7
7
8
8
9
9
10
10
11
12
11
12
WS-X4148-RJ
4 PORT
10/100 B