Removing and Replacing Blower Modules
Step 2
Install the new blower module into the chassis (
Figure 7-17
):
a.
Lift the blower module (with two hands) and slide it halfway into the module
bay.
b.
Slowly push the blower module into the chassis until it mates with the
backplane connector at the back of the module bay.
Caution
To prevent damage to the connectors, do not use excessive force when inserting
the blower module into the chassis.
c.
Tighten the captive screws on the blower module to secure it to the chassis.
•
The (green) OK status indicator on the front of the blower module should
light. If the OK indicator does not light, see the
“Troubleshooting the Blower
Installation” section on page 7-28
.
Figure 7-17 Installing the Upper Blower Module