VCC-G20E30B
Rev.900-718-34
©2014 CIS Corporation. All rights reserved.
13
3.0
μ
s
99
μ
s
Exposure = (Trigger Pulse Width) +96
μ
s
Trigger Input
Exposure Time
(Discharge)
(Readout)
Cautions for Trigger Shutter Modes
Caution 1: When the next trigger is input before the completion of video signals output for the prior
trigger, the images could be improper.
Caution 2: Smear or blooming could occur when strong incident light is extensively illuminated, with
setting the electric shutter at high speed. To avoid this smear or blooming, lower the volume of
incident light or use a stroboscopic light source to control the light volume.
Caution 3: Please refer to the exposure timing chart below for 30fps mode for the actual timing to start
exposure after adding trigger input, and or for the actual timing to complete exposure at pulse width
trigger shutter operation.
HD/VD Input Impedance Selection
SW8
OFF
HD/VD Input Impedance
10kΩ
ON
HD/VD Input Impedance
75Ω
Frame Rate Speed Selection
SW9
OFF
30fps Mode
CLK= 14.318MHz
ON
60fps Mode
CLK= 28.636MHz
When changing pixel clock, please reboot the camera power.
HD/VD Input and Output Selection
SW10 OFF
HD/VD Output
ON
HD/VD Input
(Internal/External Sync can be recognized automatically.)
Indicates initial setting position