VCC-G20E30B
Rev.900-718-34
©2014 CIS Corporation. All rights reserved.
6
Item
Specification
Optical axis accuracy Refer to drawing for CCD Optical Axis Accuracy (Clause 8)
Gain variable range
0
~
12dB (guaranateed range)
Gamma
1 (fixed)
Shutter speed
variable range
<Normal Shutter Mode>
30fps mode: OFF(1/30), 1/125, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/10000s
60fps mode: OFF(1/60), 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/8000, 1/20000s
<Trigger Shutter Mode>
30fps mode:1/100, 1/125, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/10000s
60fps mode:1/200, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/8000, 1/20000s
Pulse Width: 100
μ~
250ms
Shutter Mode
Normal Shutter Mode, Restart/Reset Mode,
Fixed Trigger Shutter Mode, Pulse Width Trigger Shutter Mode
Safety/Quality
standards
UL: Conform to UL Standard including materials and others.
RoHS: Conform to RoHS
CE: Conform to EN55022:2006 (Class B) for Emmission
Conform to EN61000-6-2: 2005 for Immunity
FCC: FCC Class A digital Device
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
Durability
Vibration
Acceleration
98 m/s
2
(10.0G)
Frequency
20
~
200 Hz
Direction
XYZ 3 directions
Testing time
120 min for each direction
Shock
No malfunction shall be occurred with 980m/s
2
(100G) for
±
X,
±
Y,
±
Z, 6 directions. (without package)
Operation environment
Temperature Operation guaranteed: -5
℃~
+45
℃
Performance guaranteed: 0
℃~
+40
℃
Humidity
RH 20
~
80% with no condensation
Storage environment
Temperature -25
℃
~
+60
℃
Humidity
RH 20
~
80% with no condensation