background image

VCC-G20E30B 

 

    Rev.900-718-34

 

©2014 CIS Corporation. All rights reserved. 

 

10 

±5

μ

s

f

h

 

±5

μ

s

VD Reset Pulse

16.0

μ

s

32.0

μ

s

1HD  63.56

μ

s

External HD

External VD

2nd Field

1st Field

ODD Field Exposure

EVEN Field Exposure

242.5H

External HD

WEN Output

20H

External VD

1H

262.5H min

(1V min)

Video Output

10H

252.5H

(Internal VD)

ODD Image

EVEN Image

 

Table of Settings 

  Operation  Mode 

 
Function 

Normal 
Shutter Mode 

Restart/Reset 
Mode 

Fixed Trigger 
Shutter Mode   

Pulse Width 
Trigger Shutter 
Mode   

2:1 Interlaced 

 

 

× 

(One side field) 

× 

(One side field) 

Field/Frame 

 

 

 

 

Shutter  Speed  Settings  by

 

rear switch 

 

× 

 

 

Shutter  Speed  Settings  by 

trigger pulse width 

× 

× 

 

 

HD/VD Input 

 

 

 

 

HD/VD Output 

 

× 

 

 

 

Normal Shutter Mode 

At normal shutter mode, consecutive video signals are read with EIA compliant 2:1 interlaced scanning. 
With shutter function, rapidly moving objects can be captured clearly.     
When  adding  external  sync  input,  please  follow  the  HD/VD  input  conditions  shown  below  for  30fps 
mode. 
 
 
 
 
 
 
 
 

 
 

Restart-Reset Mode 

With adding EXT VD at random timing with over 1VD, data for one screen image is read out.    This 
function is useful when sensitivity with regular exposure time is not sufficient or when indicating the 
locus of moving object.    ODD/EVEN field is determined by EXT HD/VD phase.     

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for VCC-G20E30B

Page 1: ...VCC G20E30B Rev 900 718 34 2014 CIS Corporation All rights reserved Analog I F 29mm Cubic EIA Analog B W Camera VCC G20E30B Product Specification Operational Manual CIS Corporation English...

Page 2: ...Input Output Signal Specification 7 4 3 CCD Spectral Response Representative value 8 5 Function Settings 8 6 External Connector Pin Assignment 14 7 Timing Chart 15 7 1 Horizontal Sync Timing 15 7 2 V...

Page 3: ...ic radiation such as radio or TV transmitters Places subject to fluorescent light reflections Places subject to unstable flickering etc lighting conditions Places subject to strong vibration Do not ap...

Page 4: ...HD VD sync input or Trigger input are valid 1 100s 1 10 000s 8 steps shutter speed can be set by rear switch as fixed trigger shutter 100 s 250ms shutter speed can be set by trigger pulse width as pu...

Page 5: ...CLK Vertical Frequency 1 60s 2 1 Interlaced 59 94 Hz Scanning lines 525H 1 120s Non Interlaced 119 9 Hz Scanning lines 262 5H Sync system Internal sync HD VD external sync Internal External recognized...

Page 6: ...standards UL Conform to UL Standard including materials and others RoHS Conform to RoHS CE Conform to EN55022 2006 Class B for Emmission Conform to EN61000 6 2 2005 for Immunity FCC FCC Class A digit...

Page 7: ...difference HD VD under 0 5 s Jitter under 20ns HD VD 75 10K SW 100 4 7K 33K 47pF 3 3V IN OUT CMOS 5V WEN output CMOS 74VHC04 equivalent Output impedance 100 HD VD WEN output signal level Low 0 5V max...

Page 8: ...Shutter Speed 8 steps At 30fps OFF 1 30s 1 10000s At 60fps OFF 1 60s 1 20000s Field Frame 2 ES1 3 ES0 4 FLD FRM 5 Mode2 Shutter Mode Normal Shutter Mode Restart Reset Mode Trigger Shutter Mode 6 Mode1...

Page 9: ...OFF OFF OFF OFF 1 60s 16 7 ms 5 0 ms OFF OFF ON 1 250 s 4 0 ms 4 0 ms OFF ON OFF 1 500 s 2 0 ms 2 0 ms OFF ON ON 1 1000 s 1 0 ms 1 0 ms ON OFF OFF 1 2000 s 493 s 494 s ON OFF ON 1 4000 s 239 s 240 s O...

Page 10: ...de field Field Frame Shutter Speed Settings by rear switch Shutter Speed Settings by trigger pulse width HD VD Input HD VD Output Normal Shutter Mode At normal shutter mode consecutive video signals a...

Page 11: ...1 2H Internal VD Composite Sync and WEN signals are one to one correspondence to trigger input so that capturing images can be done with any output signals HD VD sync signals are not necessary basica...

Page 12: ...gnals are read out after 1 2H Internal VD Composite Sync and WEN signals are one to one correspondence to trigger input so that capturing images can be done with any output signals HD VD sync signals...

Page 13: ...volume of incident light or use a stroboscopic light source to control the light volume Caution 3 Please refer to the exposure timing chart below for 30fps mode for the actual timing to start exposur...

Page 14: ...rporation All rights reserved 14 6 External Connector Pin Assignment 12 pins Circular Connector SNH 10 12 RPCB SAMWOO Pin No 1 GND 2 Power In DC 12V 3 GND 4 Video Out 5 GND 6 HD In Out 7 VD In Out 8 G...

Page 15: ...47 Effective Lines ODD Field 262 5H 247 1 6 Effective Lines Vertical Blanking Video Output Video Active Period 242 5H Camera VD 9 494 492 493 491 1 3 9 8 Transmit Black 2 6 8 494 492 WEN Output 20H Ve...

Page 16: ...The center of effective pixels shall be within f 0 6 to the center of lens mount Inclination of effective pixels Theta to datum plane shall be 0 5 Dimension from datum plane to the center of lens moun...

Page 17: ...VCC G20E30B Rev 900 718 34 2014 CIS Corporation All rights reserved 17 9 Dimensions...

Page 18: ...ication operation manual In case damage or losses are caused by use contrary to the instructions in this product specification operation manual In case damage or losses are caused by malfunction or ot...