VCC-G20E30B
Rev.900-718-34
©2014 CIS Corporation. All rights reserved.
11
242.5H
Internal HD
WEN Output
20H
Internal VD
1
~
2H
Video Output
10H
Trigger Input
252.5H
Pulse Width: 4
μ
s
~
250ms
Exposure Time
Setting time by Rear dip switch
242.5H
External HD
WEN Output
20H
External VD
1H
Video Output
10H
Trigger Input
10
μ
s
~
65ms
Pulse Width: 4
μ
s
~
250ms
Exposure Time
252.5H
(Internal VD)
Setting time by Rear dip switch
Fixed Trigger Shutter Mode
Exposure time shall be the value set by the rear switch.
In case of SYNC Reset mode
Internal VD is reset after completion of exposure and video output signals are read out after 1
~
2H.
Internal VD, Composite Sync, and WEN signals are one-to-one correspondence to trigger input so that
capturing images can be done with any output signals.
HD/VD sync signals are not necessary basically, but signals can be synchronized with internal HD with
inputing HD signals externally.
Exposure time = when setting with switch SW 1
~
4: 1/100
~
1/10000s at 30fps.
1/200
~
1/20000s at 60fps.
In case of SYNC Non-Reset mode
Video output signals are read out at the first VD position generated after completion of exposure.
Single VD should be input between 10
μ
s
~
65ms after completion of exposure.
External VD input, Composite Sync, and WEN signals are one-to-one correspondence so that any
signals can be used to capture images.
Exposure time = when setting with switch SW 1
~
4: 1/100
~
1/10000s at 30fps.
1/200
~
1/20000s at 60fps.