background image

 

1: Introduction

 

1.1

 

The  SmartZone  G5  eHandle
electronic locking options for Panduit Standard Cabinets monitored and controlled through the Panduit 
SmartZone G5 PDU. 
 

1.2

 

There are five configuration options available 
 

SKU No 

P

EA9502 

EH01

EA9500 

EH02

EA9503 

EH03

EA9501 

EH04

 

1.3

 

The eHandle accessories and harnesses supported by the SmartZone G5 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

P/N 

ACF10 

eHandle

ACF11 

eHandle

ACF20 

eHandle

ACF30 

eHandle

ACF31 

eHandle

ACF32 

eHandle

ACF33 

eHandle

ACF34 

eHandle

ACF35 

eHandle

ACF36 

eHandle

ACF37 

eHandle

ACF38 

eHandle

ACF39 

eHandle

ACF40 

eHandle

ACF41 

eHandle

1.

 

The tumbler locking mechanism should only operate when combined with the 
corresponding key for the same option group. 

2.

 

The Standard Tumbler should only operate when combined with the Standard Key.

eHandle  products  are  intended  to  provide  access  control  solution

for Panduit Standard Cabinets monitored and controlled through the Panduit 

There are five configuration options available for the eHandle family products as the following:

P/N

 

Description

 

EH01 

eHandle RFID (125kHz / 13.56MHz) with integral humidity sensor 

EH02 

eHandle  RFID  (125kHz  /  13.56MHz)  and  Keypad  with  integral 
humidity sensor 

EH03 

eHandle No Card Reader with integral humidity senso

EH04 

eHandle  No  Card  Reader  with  Keypad 
sensor 

ccessories and harnesses supported by the SmartZone G5 eHandle

Description 

eHandle (1) Temperature and (1) Door Sensor 
eHandle (3) Temperature Sensors and (1) Door Sensor
eHandle to Panduit G5 PDU Harness 
eHandle Standard Key (10 pack) 
eHandle Alternate Key Option 1 (10 pack) 
eHandle Alternate Key Option 2 (10 pack) 
eHandle Alternate Key Option 3 (10 pack) 
eHandle Alternate Key Option 4 (10 pack) 
eHandle Alternate Key Option 5 (10 pack) 
eHandle Standard Tumbler (10 pack) 
eHandle Alternate Tumbler Option 1 (10 pack) 
eHandle Alternate Tumbler Option 2 (10 pack) 
eHandle Alternate Tumbler Option 3 (10 pack) 
eHandle Alternate Tumbler Option 4 (10 pack) 
eHandle Alternate Tumbler Option 5 (10 pack) 

The tumbler locking mechanism should only operate when combined with the 
corresponding key for the same option group.   
The Standard Tumbler should only operate when combined with the Standard Key.

solutions  with  a  series  of 

for Panduit Standard Cabinets monitored and controlled through the Panduit 

family products as the following: 

RFID (125kHz / 13.56MHz) with integral humidity sensor   

RFID  (125kHz  /  13.56MHz)  and  Keypad  with  integral 

No Card Reader with integral humidity sensor 

Keypad  with  integral  humidity 

eHandle products are listed below:   

Door Sensor 

The tumbler locking mechanism should only operate when combined with the 

The Standard Tumbler should only operate when combined with the Standard Key. 

Summary of Contents for ACF10

Page 1: ...Electronic Rack User Manual Electronic Rack eHandle User Manual...

Page 2: ...ting Option for Front and Rear Door 4 eHandle WEB Configuration 4 1 ID User Authorization Add Card 4 2 Rack Access Settings 4 3 eHandle Settings 4 4 Keypad Settings 4 5 Remote Control 4 6 Beacon Setti...

Page 3: ...Handle No Card Reader with Keypad sensor ccessories and harnesses supported by the SmartZone G5 eHandle Description eHandle 1 Temperature and 1 Door Sensor eHandle 3 Temperature Sensors and 1 Door Sen...

Page 4: ...be less than 500mA 5VDC Maximum peak stall operating current shall be less than 1 150mA 5VDC Four types of Handles are listed below Electronic Rack eHandle Overview unctions shall receive power via R...

Page 5: ...al humidity sensor Remote lock unlock capability RF support to be disabled in factory firmware mode eHandle No Card Reader and Keypad with integral humidity sensor Support User pin authentication Phys...

Page 6: ...F10 Electronic Rack eHandle harness sensors and accessories Front door with wire harness with 1 door position magnetic dry contact sensor and 3 temperature sensors Rear door with wire harness with 1 d...

Page 7: ...ation TBD Handles supported on Horizontal Vertical PowerShare Non 4 Mechanical Requirements 4 1 Cutout dimensions Cutout width 25mm 0 3 0 Cutout height 150mm 0 3 General Features compatible with all a...

Page 8: ...al Dimensions Cross sectional width 7 9mm 0 0 1 Cross sectional height 7 9mm 0 0 1 Shaft Protrusion Depth 3 75mm Central Thread M6 threaded hole 10mm deep 4 6 Grip Range with 2mm offset CAM 17 5mm 4 7...

Page 9: ...es Identification numbering must not come off through expected 7 year usage No printing to be present on the surface of the keypad Hand or Left Hand installation Harness shall be routed to the side of...

Page 10: ...er autolock time Blinking Red Autolock Time Card Swipe Auth success Blinking Green Autolock Time Card Swipe Auth fail Blinking Red 3 times eHandle Mechanical lock is open by Key Blinking Magenta Door...

Page 11: ...lowing default configuration Color Default Description Blue Green White Magenta Green Identify rack location High Intensity Customized color Red Any critical alarm in the system Yellow Any warning ala...

Page 12: ...eHandle EH01 eHandle RFID 125kHz 13 56MHz with integral humidity sensor EH02 eHandle RFID 125kHz 13 56MHz and Keypad with integral humidity sensor EH03 eHandle No Card Reader with integral humidity s...

Page 13: ...3 2 eHandle Included Installation Parts Included Installation Parts 13...

Page 14: ...face of the cabinet door Use the 12mm Top Mounting Screws and Top Mounting Bracket to secure the lock to the door 3 3 3 Select a suitable Rotation Limiter standard or extended and mount the cam assem...

Page 15: ...Actions Add Card WEB Configuration 4 1 ID User Authorization Add Card Once connected users can be assigned HID cards to complete authentication authorization PDU web by ip address can get from PDU scr...

Page 16: ...ser Name up to 31 characters long Note User name is related to filed name 4 Expiration time is only applicable to temporary users After the expiry Date Time the expired ID code will no longer be valid...

Page 17: ...ontrol Two options can be selected which are Hot Cold Combined and hen this is selected aisle control is individual Hot aisle hen this is selected one aisle can be controlled by opposite aisle Time an...

Page 18: ...Smart Rack Access Control Actions Keypad Settings Keypad Settings can be achieved through WEB interface or SNMP 1 PIN Code length 1 to 15 numeric digits 0 to 9 default is blank can be updated in WEB a...

Page 19: ...dden way such a invisible by the user or readable plain text This is configurable by pin mode in WEB GUI Graphical User Interface When pin mode is active pin is hidden and displayed as When pin mode i...

Page 20: ...icking Lock Unlock on the interface can realize the remote control of the eHandle on site But actually clicking Unlock on the interface the Status on the panel is LOCK Clicking Lock on the interface t...

Page 21: ...o use this card will be recorded in PDU event log Both of event log and data log can be can be unlocked by remote control Once Authentication is received and lock mechanism is opened Lock mechanism st...

Page 22: ...cted in the dropdown Locate This is employed to locate the rack in the data center When locate is selected beacon will blink with user selected color helping the user to identify the rack in data cent...

Page 23: ...function of Standby On LED stays 4 Colors Green Blue Magenta and White Access Control Actions Status LED Settings stays solid and the default color is Green 4 Colors Green Blue Magenta and White can...

Page 24: ...Electronic Rack eHandle User Manual 24 eHandle status is shown in PDU Security section When swiping HID card to unlock the eHandle the status still shows Lock...

Page 25: ...to provide reasonable protection against harmful interference in This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions...

Page 26: ...e product conforms to RIFD specifications and technical standards 2 The product conforms to DOC declaration 3 The product meets the basic requirements and other relevant provisions of the 2014 53 EU d...

Reviews: