Cirronet CR-SEH User Manual Download Page 1

CR-SEH & CR-SEH/X 

Wireless Ethernet Bridge 

 

 

 

User’s Manual 

 
 
 
 

 

5375 Oakbrook Parkway 

Norcross, Georgia  30093 

www.cirronet.com 

(678) 684-2000 

Summary of Contents for CR-SEH

Page 1: ...CR SEH CR SEH X Wireless Ethernet Bridge User s Manual 5375 Oakbrook Parkway Norcross Georgia 30093 www cirronet com 678 684 2000...

Page 2: ...same information Any other mode of operation using this antenna is forbidden Notice to users installers using the following fixed antennas with Cirronet RF products Andrews 24dBi parabolic dish Andre...

Page 3: ...ransceiver EN 55022 EN 55024 EN 300 328 EN 301 489 1 17 EN 60950 Canadian Department of Communications Industry Canada IC Notice Canadian Department of Communications Industry Canada IC Notice This ap...

Page 4: ...ust have the interconnecting multi conductor cable run in approved conduit for the location The cable must be in the conduit until out of the Hazardous Location and the conduit must be gas tight so no...

Page 5: ...ility 8 HTML Setup 11 Console Port 14 Filtering 15 DHCP 15 CR SEH Operation 16 Overview 16 Security Modes 16 Point to Point Mode 16 Point to Multipoint Mode 17 Co located Networks 17 CR SEH Command Se...

Page 6: ...the network connection Communication between CR SEH products is performed using the WIT2411 over the air protocol Thus the CR SEH products are 802 3 compatible but not 802 11 compatible and provides...

Page 7: ...e Master The default settings in the CR SEHs are sufficient to allow connection to Ethernet networks and to have the slave CR SEH connect with the master Other steps you may want to take include Enter...

Page 8: ...100BaseT Ethernet connector is the standard RJ 45 connector and is located on the bottom front of the CR SEH The CR SEH is set up to use a straight through cable to connect to a PC If a straight throu...

Page 9: ...ecting and disconnecting the power connector The Ethernet LEDs include LINK TXD and RXD The LINK LED lights when a valid Ethernet connection is made The CR SEH is set up to use a straight through cabl...

Page 10: ...hese cables may be ordered from Cirronet in lengths of 100 feet to 300 feet in 100 foot increments Figure 3 CR SEHX Front Panel Diagram The remote radio assembly has mounting holes to secure the anten...

Page 11: ...ls are provided for special applications where multiple master CR SEHs are co located The synchronizing signals are RS 485 levels and may be connected using an RJ 11 connector If the sync signals are...

Page 12: ...CR SEH must be connected to the uplink port on the hub TXD and RXD are indicators of Ethernet data activity They indicate the transmission and reception of data over the Ethernet connection Note that...

Page 13: ...H from the DHCP server on the Master CR SEH s local network If the slave CR SEH cannot establish a link with the master CR SEH due to different network numbers or some other configuration setting the...

Page 14: ...ch for Cirronet devices Only Cirronet Ethernet devices will be displayed as shown below Ethernet devices from other manufacturers will not be displayed even if they have no IP address Any devices foun...

Page 15: ...address and the default netmask will automatically be entered as shown below A new Host Name may be entered if desired however the MAC Address cannot be changed Click OK and the IP address will be en...

Page 16: ...p session in a browser window The login screen will display as shown below Enter the default Username admin and the default Password Cirronet case sensitive The password will be displayed as dots only...

Page 17: ...lt Route enter DNS entries or change the Outmax upload download ratio for the radio setting If the CR SEH is to transmit data to devices not on its subnet a default router must be specified To set the...

Page 18: ...word Verify fields Selecting Yes allows entries to be entered into the fields Details on these settings are provided in the section on Bridge Commands Bridge Connection Status This dialog displays sta...

Page 19: ...settings for the console port are 38400 baud 8 data bits 1 stop bit and no parity The WinSEM program can be used to set up the CR SEH through the Console port The appropriate serial port must be selec...

Page 20: ...st and or broadcast packets to slow the overall performance of the CR SEH Based on the number of broadcast and multicast packets they can consume a substantial amount of the RF bandwidth By turning fi...

Page 21: ...access ip add command is used to add specific IP addresses from which telnet sessions will be allowed Up to 10 IP addresses can be entered This featured is defaulted OFF and is enabled through the ac...

Page 22: ...roughput even at the expense of some throughput for the slaves This is the factory default configuration In frequency hopping technology the following applies the shorter the hop duration the lower th...

Page 23: ...o be synchronized as to when they send to slaves and when they receive from slaves This synchronization is allowed by the FCC in the United States The FCC does not allow synchronizing of the hop seque...

Page 24: ...sk ping ipaddr Pings TCP IP host reset Resets the CR SEH activating changed configuration parameters route help add default gwaddr netmask del ipaddr list Displays help screen for command Adds IP addr...

Page 25: ...aved parameters into active memory Also causes the CR SEH to reinitialize which can take 30 seconds If reset is issued before the save command the new parameters are lost and the last saved parameters...

Page 26: ...mode filter disable turns filtering off filter bcast filters out broadcast and multicast packet while filter mcast filters out just multicast packets filter show displays the filter settings login Tu...

Page 27: ...mmand The default setting is disabled console disable removes the password requirement ip enable sets limitations set on initiating a telnet session to the CR SEH When enabled only network devices wit...

Page 28: ...attern of the radio in the CR SEH Master only The fcc command enables the FCC rules regarding synchronization of frequencies when CR SEH masters are co located and synced using the sync signals The sy...

Page 29: ...802 11b channel avoided refers to the center frequency of the 802 11b channel slave list displays the serial numbers of the radios in the CR SEHs that are currently registered with the CR SEH disconn...

Page 30: ...ow 10dBm high 18dBm Default Sets radio output power show Displays radio parameters that have been modified from factory settings radio spid 0 254 Displays service provider ID Sets service provider ID...

Page 31: ...n to be used show This command displays a list of the current radio parameters including the network number maxremotes and the sys outmax value spid The CR SEH has 64 different network numbers hopping...

Page 32: ...t NEMA 4X UV stabilized polycarbonate Dimensions Network Interface Unit 201 x 144 x 53 mm 7 9 x 5 7 x 2 1 Remote Radio Unit 266 x 246 x 59mm 10 5 x 9 4 x 2 3 CR SEHX only Operating Temperature Network...

Page 33: ...st is being used to initiate the telnet session The CR SEH does not respond through the Console Port Check that a straight through serial cable is being used if connected to a PC If you are not using...

Page 34: ...to the goods such as but not limited to power failure No suit or action shall be brought against Seller more than twelve 12 months after the related cause of action has occurred Buyer has not relied...