Section 11: Rework and Guided Assembly / Guided Assembly
1000R+ User’s Guide / page 58
7.
Connect the next set of points prompted by the analyzer. If the connection is
correct, the analyzer willdisplay
Attach JX-XX to JX-XX
.
8.
Repeat the last step by connecting the next set of points prompted. If you create
a short, the analyzer will prompt
Break
JX-XX
.
9.
Continue connecting points as prompted by the 1000R+ until the analyzer
prompts
Good Cable
or
Ready To Hipot
. This indicates you have finished
wiring the assembly.
Building cables that have one end terminated with a connector
To build cables that have only one end terminated, follow these steps:
1.
Following the documentation for the kind of cable you want to build, install the
right cable adapters onto the analyzer, and replace the cover plate.
2.
Either connect a Sample Cable of the kind you want to build to the analyzer, or
retrieve the wirelist for the kind of cable you want to build from the analyzer’s
memory (see page 29 for instructions on how to do this). If you use a wirelist
retrieved from memory, skip step 3 and go directly to step 4.
3.
Turn on the analyzer and learn the Sample Cable, then disconnect the Sample
Cable.
4.
Insert the connector on the terminated end of the cable into the cable adapter on
the analyzer.
5.
Insert an empty connector of the type correct for the cable into the other cable
adapter on the analyzer.
6.
Plug the probe into the
Probe
jack on the back of the analyzer.
7.
Make the first connection specified in your cable’s documentation. The analyzer
should prompt
Open Detected
.
•
If the analyzer prompts
Errors Detected
, you have created a short
instead of connecting the two points that should be connected. Break
the short, check your build list, and try again until the analyzer prompts
Open Detected
.
8.
Press
Display/Print
to enter rework mode.
9.
Probe the loose end of one of the wires. The display will prompt Probe On
JX-
XXX
. Connect this wire to the appropriate pin on the empty connector, according
to your cable documentation.
10. If you create an error, the display will read
Break JX-XXX
. Remove the error,
then try reconnecting the loose wire at the correct position.
11. Continue until the display reads either
Good Cable
, or
Ready to Hipot
.
Summary of Contents for Signature 1000R+
Page 1: ...Signature 1000R Cable Analyzer User s Guide Version 4 0 Major Revision 23 September 1999...
Page 3: ......
Page 5: ...1000R User s Guide page 6...
Page 7: ...Introduction to the Cirris 1000R What your order should contain 1000R User s Guide page 8...
Page 15: ...Section 1 Work With the Hardware Changing the company name 1000R User s Guide page 16...
Page 20: ...Section 3 What the Option Settings Mean Auto Print 1000R User s Guide page 21...
Page 21: ...Section 3 What the Option Settings Mean Auto Print 1000R User s Guide page 22...
Page 51: ...Section 10 Select a Test Procedure Testing harnesses and backplanes 1000R User s Guide page 52...
Page 71: ...Section 13 Specifications Warranty 1000R User s Guide page 72...
Page 73: ...Section 14 Statement of Warranty 1000R User s Guide page 74...
Page 77: ...Section 15 Glossary short 1000R User s Guide page 78...
Page 79: ...Section 16 Blank Forms to Photocopy 1000R User s Guide page 80...
Page 81: ......
Page 83: ......
Page 88: ......