1000R+ User’s Guide / page 53
The hand-held test
probe
You can connect a hand-held test probe (provided with your analyzer) to the 1000R+.
It will help you quickly identify test points as you rework or assemble cables.
Note
:
The probe works only when the analyzer is in the rework mode. It will not function
when the analyzer prompts
Ready to Test
or
Please Verify
.
Installing the probe
Plug the probe into the connector labeled
Probe
on the back of the analyzer. This
photo shows the location of the probe jack.
Example: Identifying
test points using the
probe
While the analyzer is in the test mode, touch the tip of the probe to the connector pin
or wire you want to identify. For example, if you touch the probe tip to position J1,
pin 11, the analyzer will prompt
Probe On J1-11
.
Plug the probe
in here
PROBE ON J1-11
.
Section 11:
Rework and
Guided
Assembly
Summary of Contents for Signature 1000R+
Page 1: ...Signature 1000R Cable Analyzer User s Guide Version 4 0 Major Revision 23 September 1999...
Page 3: ......
Page 5: ...1000R User s Guide page 6...
Page 7: ...Introduction to the Cirris 1000R What your order should contain 1000R User s Guide page 8...
Page 15: ...Section 1 Work With the Hardware Changing the company name 1000R User s Guide page 16...
Page 20: ...Section 3 What the Option Settings Mean Auto Print 1000R User s Guide page 21...
Page 21: ...Section 3 What the Option Settings Mean Auto Print 1000R User s Guide page 22...
Page 51: ...Section 10 Select a Test Procedure Testing harnesses and backplanes 1000R User s Guide page 52...
Page 71: ...Section 13 Specifications Warranty 1000R User s Guide page 72...
Page 73: ...Section 14 Statement of Warranty 1000R User s Guide page 74...
Page 77: ...Section 15 Glossary short 1000R User s Guide page 78...
Page 79: ...Section 16 Blank Forms to Photocopy 1000R User s Guide page 80...
Page 81: ......
Page 83: ......
Page 88: ......