11
Instruction Manual
Wibeee Max
3�3�1�1�- Scale selection
The
FLEX Wibeee 25
current sensors indicate the selected scale through the
blue
LED on
their head.
During the first 20 seconds after being switched on, the
Wibeee Max
is in the scale selection
period. The
blue
LED flashes quickly and indicates the selected scale.
Press the
RESET
key during this period to select the desired scale:
One blink indicates that the
350 A
scale has been selected.
Two blinks indicate that the
700 A
scale has been selected.
When the scale selection period has ended, the quick blinking light is deactivated and the
blue
LED indicates the selected scale at regular intervals.
3�3�2�- Wibeee Max Plus
In the
Wibeee Max Plus
model, current measurement is performed using the
FLEX Wibeee
54
flexible sensors.
Table 6:Metrological characteristics�
FLEX Wibeee 54
Measurement scales
100
1 k
5 k
Nominal range
100 A
1000 A
5000 A
Output / input ratio
10.0 mV/A
1.0 mV/A
0.2 mV/A
Range of use
1 ... 100 A
10 ... 1000 A
50 ... 5000 A
Specified measurement range
10 ... 100
100 ... 1000
500 ... 5000
Typical phase difference
1st
1st
1st
The measurement uncertainty is for the sensor in its optimal position, with no external electric
or magnetic fields and within the working temperature range,
Table 7:Position error
Position
Error
A
B
A
± 1%
B
A ± 3%