5�3�4�- GENERAL OPTIONS

Figure 32

 shows the 

General Options

 section.

Figure 32:Internal web server: General Options�

You can configure the following parameters in this section:

Connection Type:

 Connection type

Measures Refresh Time (s):

 The measurement refresh time.

Data Refresh Time (min):

 The data refresh time. If the value is set to -1, the sending of data 

is deactivated.

Offline HD Save Time (min): 

 If the device loses its connection, the data measured is stored 

in an internal memory. In this section, you set the frequency with which data is stored in the 

memory. If the value is set to -1, the saving of data is deactivated.

It is also possible to reset the energy meter, by pressing the 

 button.

Summary of Contents for Wibeee Max

Page 1: ...INSTRUCTION MANUAL Consumption analysers M169B01 03 18A ...

Page 2: ...2 Wibeee Max Instruction Manual ...

Page 3: ...ully prior to connecting the unit Follow all installation and maintenance instructions throughout the unit s working life Pay special attention to the installation stan dards of the National Electrical Code Refer to the instruction manual before using the unit In this manual if the instructions marked with this symbol are not respected or carried out correctly it can result in injury or damage to ...

Page 4: ... 4 2 MEASUREMENT PARAMETERS 17 4 3 LED INDICATORS 17 4 4 KEY 18 4 5 START UP 18 5 DISPLAY AND CONFIGURATION 20 5 1 MOBILE APPLICATION 20 5 2 WEB PLATFORM 21 5 2 1 HOME 22 5 2 2 DASHBOARD 26 5 2 3 DEVICES 27 5 2 4 NOTIFICATIONS 27 5 2 5 REPORTS 28 5 2 6 HELP 30 5 3 INTERNAL WEB SERVER 30 5 3 1 INSTANT DATA 31 5 3 2 NETWORK 32 5 3 3 ADVANCED OPTIONS 32 5 3 4 GENERAL OPTIONS 33 5 4 CONFIGURATION THRO...

Page 5: ...mages of the devices are for illustration purposes only and may differ from the orig inal device SYMBOLS Table 2 Symbols Symbol Description Compliant with the relevant European standards Double insulation AC current Device covered by European directive 2002 96 EC At the end of its useful life do not leave the device in a household waste container Follow local regulations on electronic equipment re...

Page 6: ...ON OF THE PRODUCT The Wibeee Max is a device that measures three phase lines and is connected to the cloud via the Wibeee platform The device has been designed to make the installation process as simple as possible It also has an internal memory that allows information to be recovered in the event of a temporary loss of the Wi Fi connection There are 2 models available Wibeee Max with two scales f...

Page 7: ...essential to keep the cables in a perfect condition to avoid accidents personal injury and damage to installations Limit the operation of the device to measuring the specified current or voltage values The manufacturer of the device shall not be held responsible for any damage resulting from the user or installation company failing to observe the warnings and or recommendations indicated in this m...

Page 8: ... uninsulated conductors is limited to 600 V or DC to frequencies below 1kHz Do not expose the device to aggressive or explosive environments Do not use the device if you have any reason to believe that it is not working correctly or it is defective For measuring of uninsulated conductors use the appropriate and necessary personal protective equipment The device should be installed after the circui...

Page 9: ...t and if it is not used and it interferes with another type of installation it may be broken 3 Connect the device See 3 4 DEVICE TERMINALS y 3 5 CONNECTION DIAGRAMS 4 Once the Wibeee Max has been connected to the auxiliary power supply check that the red LED is on and flashing see 4 3 LED INDICATORS 5 Select the measurement scale for the current sensors The Wibeee Max model following the steps ind...

Page 10: ...its optimal position with no external electric or magnetic fields and within the working temperature range Table 4 Table 4 Position error Position Error A B A 1 B A 3 Table 5 Variations in range of use Variations in range of use Magnitude of Influence Range of influence Typical Maximum Temperature 10ºC 60ºC 0 3 ºC Relative humidity 10 90 0 3 Conductor position 2 3 Adjacent conductor D 4 300 A 2 Se...

Page 11: ... the quick blinking light is deactivated and the blue LED indicates the selected scale at regular intervals 3 3 2 Wibeee Max Plus In the Wibeee Max Plus model current measurement is performed using the FLEX Wibeee 54 flexible sensors Table 6 Metrological characteristics FLEX Wibeee 54 Measurement scales 100 1 k 5 k Nominal range 100 A 1000 A 5000 A Output input ratio 10 0 mV A 1 0 mV A 0 2 mV A Ra...

Page 12: ...ors indicate the selected scale through the blue and red LEDs on their head During the first 20 seconds after being switched on the Wibeee Max Plus is in the scale selec tion period The blue and red LEDs flash slowly and indicate the selected scale Press the RESET key during this period to select the desired scale The blue LED indicates that the 100 A scale has been selected The red LED indicates ...

Page 13: ...e 1 Current measurement Black L1 Red L2 Yellow L3 2 Voltage measurement and power supply Black L1 Red L2 Yellow L3 Blue Neutral Green and Brown Power supply 1 2 Figure 3 Wibeee Max terminals 3 5 CONNECTION DIAGRAMS LOAD Power Supply Blue Black Red Yellow Brown Green Black Red Yellow L1 L2 L3 N Figure 4 Wibeee Max connection diagram ...

Page 14: ...The Wibeee Max s data can be accessed in two ways Application mode Direct share mode 3 6 1 APPLICATION MODE In application mode the data measured by the Wibeee Max is uploaded to the cloud and ac cessed using the Wibeee CIRCUTOR application When using this mode the Wibeee Max and the user who has configured it are linked so the user can control the device view the data that has been sent and the c...

Page 15: ... will send the data If you configure a Wibeee Max while using this mode there is no link between the user and the device so the only way to access the de vice when it is connected to the network is by knowing its IP address and accessing it using a search tool To start the device in direct share mode follow these steps 1 On a smartphone tablet use the Wi Fi connection s settings to connect to the ...

Page 16: ...is directly accessed from the device s inte grated web server Note The device s integrated web server can also be accessed in the application s operating mode If the Wibeee Max loses the connection with the server a back up memory with a 30 day capacity will start up This back up memory will store the values of the most critical variables voltage current apparent power active power reactive power ...

Page 17: ...V Numerical Graphical Graphical Active Power kW Numerical Graphical Graphical Reactive Power kVAr Numerical Graphical Graphical Active Energy kWh Numerical Graphical Graphical Reactive Energy kVArh Numerical Graphical Graphical Frequency Hz Numerical Graphical Graphical Power Factor Cos Φ Numerical Graphical Graphical Energy kWh Graphical CO2 Emissions kgCO2 Graphical Cost Graphical 4 3 LED INDICA...

Page 18: ...INSTALLATION Restore the device s factory settings To do this hold down the RESET button for 10 seconds until the device s red and blue LEDs simultaneously flash three times 4 5 START UP During the start up of the device the Wibeee Max goes through different states 1 Configuration state Blue LED Slow blinking light 1s Red LED Slow blinking light 1s In this state the Wibeee Max generates its own Wi...

Page 19: ...ration state and 1 attempt to connect 3 Connecting state Blue LED Fast blinking light 1s Red LED Slow blinking light 1s In this state the device has connected to the Wi Fi network and is waiting to complete the first successful transfer of data When it first manages to successfully send data it will enter the Connected and sending OK state If the device is not able to successfully send the first s...

Page 20: ...t share mode Internal Web server Web platform http wibeee circutor com Mobile application Wibeee Circutor Internal Web server Data display Figure 8 Data display based on the operating mode 5 1 MOBILE APPLICATION The Wibeee Circutor mobile application is compatible with iOS and Android and has a version for smartphones and tablets In it you can view and configure all of the parameters measured by t...

Page 21: ...ou can access the different sections of the platform Home summary of consumption displays charts and gives access to the dashboard configuration options graphical interface Dashboard displays all of the dashboards of every active device Devices access to all of the connected devices Notifications displays the notifications log Reports access to regular report generation Help help screen ...

Page 22: ...on and CO2 emissions from the previous month the current month and the forecast for the end of the month It also displays the set target value Figure 11 Summary area The area in Figure 12 shows 2 of the possible charts that can be viewed Table 10 show all of the parameters that can be graphically displayed Use the arrows to toggle between charts ...

Page 23: ...the latest measurements sent by the device Figure 13 Measurements area In the area in Figure 14 you can access the configuration options for the devices and dashboard see 5 2 1 1 Configuration screen for the devices dashboard Figure 14 Access to the device dashboard configuration area ...

Page 24: ...llowing data DEVICE Figure 15 Configuration screen Device The device s basic data is entered in this section Name The name of the device Select Dashboard Dashboard selection Mac MAC address of the device 2 4 Quadrants Measurement selection for 2 quadrants consumption or 4 quadrants consumption and generation LOCATION Figure 16 Configuration screen Location ...

Page 25: ...ion of the device COST Figure 17 Configuration screen Cost The costs are entered in this section Price kWh Price of kWh Tax Other Tax Fees and taxes Other Costs Cost day Other costs Cost kW Day Cost kW Day Cost in kW per day Billing date Billing date Contracted power kW Contracted power TARGET AND NOTIFICATIONS Figure 18 Configuration screen Target and Notifications ...

Page 26: ...tive for 3 days Overvoltage overvoltage alarm Undervoltage undervoltage alarm High consumption alarm for high consumption in the installation 5 2 2 DASHBOARD The Dashboard screen Figure 19 shows all of the active dashboards Figure 19 Dashboard Screen It is also possible to create a chart comparing different dashboards To do this simply select the dashboards that you want to compare by ticking the ...

Page 27: ...e Devices screen Figure 21 displays a list of all of the connected devices Figure 21 Devices screen 5 2 4 NOTIFICATIONS The Notifications screen Figure 22 shows a log of all of the notifications that have been generated Figure 22 Notifications screen ...

Page 28: ...Reports screen Figure 23 is divided into two areas Figure 23 Reports Screen REPORTS This section shows the scheduled reports to be regularly generated To create a new regular report press the icon The dialogue box in Figure 24 opens Figure 24 New Report ...

Page 29: ...lling period Recipients Enter the email addresses of the recipients of the report You can prepare a simple version of a report by selecting Normal Section Figure 24 where everything is pre configured and you only have to select the quantity Or an advanced version by selecting Advanced Section Figure 25 where you can configure a lot more options Figure 25 New Report Advanced Section REPORT LOG In t...

Page 30: ...stallation operation web platform and application of the Wibeee systems Figure 26 Help Screen 5 3 INTERNAL WEB SERVER Figure 27 shows the screen where you access the device s internal web server The device s default address is http 192 168 1 150 User user Password user Figure 27 Internal web server access screen ...

Page 31: ...e main screen is shown in Figure 28 Figure 28 Main screen of the internal web server 5 3 1 INSTANT DATA In this section you can access instant data from each of the measurement phases Figure 29 Figure 29 Internal web server Instant Data ...

Page 32: ...re the network parameters in the Network section Figure 30 Figure 30 Internal web server Network 5 3 3 ADVANCED OPTIONS You can configure the IP parameters in the Advanced Options section Figure 31 Figure 31 Internal web server Advanced Options wibeee circutor com ...

Page 33: ...Time s The measurement refresh time Data Refresh Time min The data refresh time If the value is set to 1 the sending of data is deactivated Offline HD Save Time min If the device loses its connection the data measured is stored in an internal memory In this section you set the frequency with which data is stored in the memory If the value is set to 1 the saving of data is deactivated It is also po...

Page 34: ... been processed by the server it sends an HTTP correct access response HTTP 200 OK 5 4 1 PARAMETER QUERY 5 4 1 1 DEVICE ID You should use the following request to view the device s ID http ip_address services user devices xml Figure 33 HPPT queries Device ID 5 4 1 2 Values of the device s variables To view the values of all of the device s variables use the following request http ip_address servic...

Page 35: ...rver var macAddr var MAC identifier var ssid var Name of the network var keyEnc var Password type var keyType var Password format Hex or ASCII var securKey var Password var serverIp var Name of the server domain var serverIpResolved var IP address of the server var serverPort var Sending port var vrms1 var Phase voltage L1 V var vrms2 var Phase voltage L2 V var vrms3 var Phase voltage L3 V var vrm...

Page 36: ... Active Energy L3 Wh var eactt var Total Active Energy Wh var ereactl1 var Inductive Reactive Energy L1 VArLh var ereactl2 var Inductive Reactive Energy L2 VArLh var ereactl3 var Inductive Reactive Energy L3 VArLh var ereactlt var Total Inductive Reactive Energy VArLh var ereactc1 var Capacitive Reactive Energy L1 VArCh var ereactc2 var Capacitive Reactive Energy L2 VArCh var ereactc3 var Capaciti...

Page 37: ... security 0 OPEN 1 WEP 5 WPA 9 WPA2 13 WPA WPA2 typekey Password encryption 1 Hexadecimal 2 PassPhrase 3 Password sending http ip_address config_value pass xxxxxxxxx id 0 9732521877158433 Table 15 Configuration HPPT variables Request 3 Variable Description pass Wi Fi password 4 Server Configuration http ip_address conFigure_server URLServidor c339a462 portServidor 1f91 id 0 33531335316222393 Table...

Page 38: ...less devices in a spe cific organisation airport hospital etc it is advisable to ask for authorisation to use wireless communications 6 2 Wi Fi COMMUNICATIONS Wi Fi is one of the most widely used wireless technologies today for connecting and exchang ing information between electronic devices without having to connect them physically The Wibeee Max has Wi Fi communications in the 2 4 GHz band comp...

Page 39: ...10 0008 Hz x 10 Total Frequency FreqTx10 0009 Hz x 10 Active Power L1 Wreal1x10 000A W x 10 Active Power L2 Wreal2x10 000B W x 10 Active Power L3 Wreal3x10 000C W x 10 Total Active Power WrealTx10 000D W x 10 L1 Reactive Power Wreact1x10 000E Var x 10 L2 Reactive Power Wreact2x10 000F Var x 10 L3 Reactive Power Wreact3x10 0010 Var x 10 Total Reactive Power WreactTx10 0011 Var x 10 Apparent Power L...

Page 40: ... kVarh Capacitive Reactive Energy L2 EreactC2 002C 002D kVarh Capacitive Reactive Energy L3 EreactC3 002E 002F kVarh Total Capacitive Reactive Energy EreactCT 0030 0031 kVarh Function 05 is used to delete energy meters Table 18 Modbus memory map Deleting parameters Deleting parameters Address Value to be sent Deleting energy meters 0000 0xFF00 ...

Page 41: ... range of use Active energy measurement 2 variations in range of use Reactive energy measurement 2 variations in range of use Frequency measurement 1 variations in range of use Power factor measurement 2 variations in range of use Variations in Range of Use Magnitude of Influence Range of influence Typical Maximum Temperature 10ºC 60ºC 0 3 Relative humidity 10 90 0 3 Crosstalk current 0 9 External...

Page 42: ...rements for electrical equipment for measurement control and laboratory use Part 1 General requirements IEC 61010 1 2001 Safety requirements for electrical equipment for measurement control and laboratory use Part 2 030 Particular requirements for testing and measuring circuits UNE EN 61010 2 030 2011 Electrical equipment for measurement control and laboratory use EMC requirements Part 1 General r...

Page 43: ...n con trary to the national electrical code or that surpasses the limits indicated in the technical and environmental features of this manual CIRCUTOR accepts no liability due to the possible damage to the unit or other parts of the installation nor will it cover any possible sanctions derived from a pos sible failure improper installation or improper usage of the unit Consequently this guarantee ...

Page 44: ...44 Wibeee Max Instruction Manual 10 CE CERTIFICATE ...

Page 45: ...45 Instruction Manual Wibeee Max ...

Page 46: ...46 Wibeee Max Instruction Manual ...

Page 47: ...47 Instruction Manual Wibeee Max ...

Page 48: ...CIRCUTOR SA Vial Sant Jordi s n 08232 Viladecavalls Barcelona Tel 34 93 745 29 00 Fax 34 93 745 29 14 www circutor com central circutor com ...

Reviews: