6.4.- MODBUS MEMORY MAP
All
MODBUS
map addresses are in hexadecimal format.
Table 17: Modbus memory map
Parameter
Symbol
Address
Units
Phase voltage L1
Vrms1x10
0000
V x 10
Phase voltage L2
Vrms2x10
0001
V x 10
Phase voltage L3
Vrms3x10
0002
V x 10
Current L1
Irms1x10
0003
A x 10
Current L2
Irms2x10
0004
A x 10
Current L3
Irms3x10
0005
A x 10
Frequency L1
Freq1x10
0006
Hz x 10
Frequency L2
Freq2x10
0007
Hz x 10
Frequency L3
Freq3x10
0008
Hz x 10
Total Frequency
FreqTx10
0009
Hz x 10
Active Power L1
Wreal1x10
000A
W x 10
Active Power L2
Wreal2x10
000B
W x 10
Active Power L3
Wreal3x10
000C
W x 10
Total Active Power
WrealTx10
000D
W x 10
L1 Reactive Power
Wreact1x10
000E
Var x 10
L2 Reactive Power
Wreact2x10
000F
Var x 10
L3 Reactive Power
Wreact3x10
0010
Var x 10
Total Reactive Power
WreactTx10
0011
Var x 10
Apparent Power L1
Waparent1x10
0012
VA x 10
Apparent Power L2
Waparent2x10
0013
VA x 10
Apparent Power L3
Waparent3x10
0014
VA x 10
Total Apparent Power
WaparentTx10
0015
VA x 10
Power Factor L1
PF1 x 100
0016
x 100
Power Factor L2
PF2 x 100
0017
x 100
Power Factor L3
PF3 x 100
0018
x 100
Total Power Factor
TPF x 100
0019
x 100
Active Energy L1
Eact1
001A - 001B
kWh
Active Energy L2
Eact2
001C - 001D
kWh
Active Energy L3
Eact3
001E - 001F
kWh
Total Active Energy
EactT
0020 - 0021
kWh
Inductive Reactive Energy L1
EreactL1
0022 - 0023
kVarh
Inductive Reactive Energy L2
EreactL2
0024 - 0025
kVarh
Inductive Reactive Energy L3
EreactL3
0026 - 0027
kVarh
Total Inductive Reactive Energy
EreactLT
0028 - 0029
kVarh