Raption
72
Service Manual
C H A R G E P O I N T L E V E L
Error
Hexadecimal
Decimal Description
OK
0x0
0
No error
CFG
0x1
1
Invalid Configuration
READER
0x2
2
Reader Error.
DISPLAY
0X4
4
Display Error.
TAMPER
0x8
8
Tamper Error.
TILT
0x10
16
Charge point is tilted.
SUPPLY
0X20
32
Power Supply dropped.
RCD
0X40
64
RCD dropped.
TEMPERATURE
0x80
128
Temperature out of range
OTHER
0x100
256
Other error not defined above.
COMMUNICATION
0x200
512
One or more devices configured on the
charge point are not communicating.
TYPE
0X400
1024
Device installed is not the same as
configured.
VERSION
0x800
2048
Incorrect device version.
GROUND
0x1000
4096
PE error.
MCB
0x2000
8192
Charge Point MCB tripped
OFFLINE
0x4000
16384
Charge point is offline