Raption
50
Service Manual
The thermostat is configured at -15ºC. If temperature is lower than this value, contactor
will open.
When K13.3 contactor opens, it does two functions simltaneously:
1 — Disconnects the supply of the internal components.
2 — Activates the heater.
So, as a result, when the Charging Station is powered and the environmental temper-
ature is lower than -15ºC this system is activated. Even being powered, the Charging
Station will remain with all the components turned off while heater is activated.
When temperature is high enough,
Raption
will start to work normally.